27ENGLISH
CLEANING
This function allows to open the burn pot base, facilitating the combustion chamber cleaning operations.
With the stove cold and switched "OFF", activate the CLEANING function.
Once the burn pot bottom has been opened completely, scrape the walls of the combustion chamber using the special tool supplied and let
the residual ash drop into the ash drawer.
CONTROLS PROCEDURE:
Press key 6
Press 3 until SETTINGS appears and conrm by pressing 6
Keep pressing 3 until CLEANING appears and conrm by pressing 6 and wait for the burn pot bottom to open.
Scrape the walls of the combustion chamber using the special tool supplied and let the residual ash drop into the ash drawer.
Press key 1 to end and wait for the main screen to reappear.
OPEN THE DOOR ONLY WHEN THE OPERATION IS COMPLETE! THE DISPLAY WILL INDICATE THAT THE DOOR HAS BEEN OPENED!
OUTLET AIR
This function allows any air in the stove to be discharged. By activating the pump function, it will be powered alternatively with 30 second
work phases and 30" stop for 15 minutes. With the stove cold and "OFF", activate the OUTLET AIR function and press 6 to conrm. To
interrupt, press and hold key 1 for 3 seconds.
Attention: before activating the "OUTLET AIR" function, make sure you have opened the vent screw of the manual vent valve.
CONTROLS PROCEDURE
Press key 6.
Press key 3 until SETTINGS appears and conrm by pressing key 6.
Press key 3 until OUTLET AIR appears and conrm by pressing key 6.
Use keys 4-5 to enable "ON" / disable "OFF"
Press key 1 several times to conrm and exit the menu.
EASY CONTROL
The function allows for two values to be set:
OFF (disabled - factory default)
ON (enabled)
Activation (EASY CONTROL = ON) is recommended in the event that there is an excessive formation of combustion residues in the ue
during operation at reduced power (see FLUE EXHAUST chapter).
Caution! It is advisable to activate the EASY CONTROL function under the supervision of a qualied technician.
CONTROLS PROCEDURE
Press key 6.
Press key 3 until SETTINGS appears and conrm by pressing key 6.
Keep pressing 3 until EASY CONTROL appears and conrm by pressing 6.
Use keys 4-5 to enable "ON" / disable "OFF"
Press key 1 several times to conrm and exit the menu.
RESET
Allows the user to reset all editable values to the default values.
CONTROLS PROCEDURE
Press key 6.
Press key 3 until SETTINGS appears and conrm by pressing key 6.
Press key 3 until RESET appears and conrm by pressing key 6.
Use keys 4-5 to enable "ON" / disable "OFF"
Press key 1 several times to conrm and exit the menu.
27


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Extraflame GUENDA IDRO at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Extraflame GUENDA IDRO in the language / languages: English as an attachment in your email.

The manual is 9.36 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Extraflame GUENDA IDRO

Extraflame GUENDA IDRO User Manual - German - 40 pages

Extraflame GUENDA IDRO User Manual - French - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info