811730
37
Zoom out
Zoom in
Previous page
1/40
Next page
37ENGLISH
**TRapDooR BloCKeD
The automatic cleaning of the burn pot is
blocked.
Burn pot dirty/clogged
The door is not closed correctly.
Check that the door closes correctly. Check that the burn pot is clear and
clean. The automatic cleaning of the burn pot is blocked.
If the problem persists, contact the service centre.
**MaX eleCTRiCal
CURRenT
The automatic cleaning of the burn pot is
blocked.
Burn pot dirty/clogged
The door is not closed correctly.
Check that the door closes correctly.
Check that the burn pot is clear and clean.
The automatic cleaning of the burn pot is blocked.
If the problem persists, contact the service centre.
*DHW pRoBe Fault in DHW PROBE probe. Contact after-sales centre
*BUFFeR TanK pRoBe Fault in BUFFER TANK probe. Contact after-sales centre
pWM inTeRFaCe
alaRM
IPWM output interface damaged, in short
circuit or not connected Contact after-sales centre
HoT pWM alaRM
The pump is operating but not with good
performance. Undervoltage 160-194v.
Pump in circuit breaker protection mode.
Contact after-sales centre
sToppeD pWM alaRM
The pump has stopped but is still operational.
Undervoltage < 160v. Overvoltage.
Unexpected external ow.
Contact after-sales centre
sToppeD 2 pWM
alaRM
The pump has stopped but is still operational.
Problem in a component dierent to the pump.
Debris in installation.
Positioning in high temperature.
Contact after-sales centre
BloCKeD pWM alaRM The pump has stopped permanently
Pump blocked. Electronic module damaged Contact after-sales centre
FloW pWM alaRM
Pump blocked.
Liquid with high density.
Pipe obstructed.
Contact after-sales centre
**DelTa-p FaUlT Dierential pressure transducer faulty or
disconnected. Contact after-sales centre
Min DelTa-p alaRM 2
The ash drawer is not closed correctly.
The air intake is clogged.
The combustion chamber is dirty.
The holes in the burn pot are clogged.
The heat exchanger and/or the fume pipe of the
appliance are dirty.
The T-shaped tting, the ue pipe or the
chimney ue are clogged.
Check hermetic closure of the ash drawer.
Clean the air intake.
Clean the combustion chamber.
Clear the burn pot holes.
Clean the heat exchanger and the fume pipe of the appliance.
Clean/clear the T-shaped tting, the ue pipe and the chimney ue.
Contact after-sales centre
* if there is an additional system data sheet ** on models with this function.
37


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Extraflame EVELYNE IDRO 2.0 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Extraflame EVELYNE IDRO 2.0 in the language / languages: English as an attachment in your email.

The manual is 10.18 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Extraflame EVELYNE IDRO 2.0

Extraflame EVELYNE IDRO 2.0 User Manual - German - 40 pages

Extraflame EVELYNE IDRO 2.0 User Manual - Dutch - 40 pages

Extraflame EVELYNE IDRO 2.0 User Manual - French - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info