811730
30
Zoom out
Zoom in
Previous page
1/40
Next page
30 ENGLISH
CLEANING AND MAINTENANCE
ALWAYS FOLLOW THE INSTRUCTIONS IN COMPLETE SAFETY!
Make sure that the power supply cable plug is disconnected, as the generator may have been programmed to turn on.
That the generator is cold all over.
That the ashes are completely cold.
Ensure ecient air exchange in the room during the product cleaning operations.
Poor cleaning will compromise correct operation and safety!
MAINTENANCE
For correct operation, the generator must undergo routine maintenance by a qualied technician, at least once a year.
The periodic inspection and maintenance operations must always be performed by specialised, qualied technicians, who operate in
accordance with the laws in force and the instructions given in this use and maintenance manual.
PERIODIC CLEANING UNDER USER’S RESPONSIBILITY
The periodic cleaning operations, as indicated in this use and maintenance manual, must be performed with the utmost care after reading the
instructions, procedures and frequency described in this use and maintenance manual.
CLEANING THE SURFACES AND COVERING
Never use abrasive or chemically aggressive detergents for cleaning!
The surfaces must be cleaned when the generator and coating are completely cold. For the maintenance of the surfaces and metal parts,
simply use a cloth dampened with water or with water and neutral soap.
Failure to follow the instructions may lead to damage to the generator surfaces and invalidate the warranty.
CLEANING THE CERAMIC GLASS
Never use abrasive or chemically aggressive detergents for cleaning!
The ceramic glass must be cleaned when the glass is completely cold.
To clean the ceramic glass, simply use a dry brush and some damp newspaper dipped in ash. If the glass is very dirty, use a specic cleaning
agent for ceramic glass. Spray a small amount on a cloth and use it on the ceramic glass. Do not spray the cleaning agent or any other liquid
directly on the glass or seals!
Failure to comply with these instructions may damage the surfaces of the ceramic glass and cause the invalidation of the warranty.
CLEANING THE PELLET HOPPER
When the hopper is completely empty, disconnect the power cord of the generator, remove the residues (dust, chippings, etc.) from the
empty hopper and then ll it up.
EVERY YEAR, HAVE THE FUME EXTRACTION SYSTEM, FLUE PIPES AND T” FITTINGS, INCLUDING THE INSPECTION
CAPS CLEANED. IF PRESENT, ALSO CLEAN THE ELBOWS AND HORIZONTAL SECTIONS!
THE GENERATOR CLEANING FREQUENCY IS INDICATIVE! IT DEPENDS ON THE QUALITY OF THE PELLET USED AND ON
HOW OFTEN IT IS USED.
THESE OPERATIONS MAY SOMETIMES NEED TO BE PERFORMED MORE OFTEN
SCRAPERS
The heat exchangers must only be cleaned when cold! Cleaning
them ensures constant heat output over time. This maintenance
must be performed at least once a day. To do this, use the scrapers
positioned in the upper part of the generator, making
upward and
downward moments several times.
THE following iMAgES ARE foR illUSTRATiVE PURPoSES.
TO FIND OUT WHERE YOUR NEAREST SERVICE CENTRE IS, CONTACT YOUR DEALER OR VISIT THE WEBSITE:
WWW.LANORDICA-EXTRAFLAME.COM
30


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Extraflame EVELYNE IDRO 2.0 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Extraflame EVELYNE IDRO 2.0 in the language / languages: English as an attachment in your email.

The manual is 10.18 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Extraflame EVELYNE IDRO 2.0

Extraflame EVELYNE IDRO 2.0 User Manual - German - 40 pages

Extraflame EVELYNE IDRO 2.0 User Manual - Dutch - 40 pages

Extraflame EVELYNE IDRO 2.0 User Manual - French - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info