22 ENGLISH
OPERATION AND LOGIC
IGNITION
Once the previously listed points have been checked, press key
for three seconds to ignite the stove.
15 minutes are available for the ignition phase. After ignition and after the control temperature has been reached, the
stove interrupts the ignition phase and switches to PREPARATION.
PREPARATION
During the PREPARATION phase, the stove stabilises combustion, increasing it progressively, to then start ventilation and switch to WORK.
WORK
During the work phase, the stove reaches the set power set; see following item.
REGULATION OF SET POWER
The set power has 5 operating levels; when the
OK
key is pressed, the set power is displayed; it can be changed using the
OK
or
OK
keys.
Power 1 = minimum level - Power 5 = maximum level.
The change must be conrmed by pressing the key
OK
.
ADJUSTMENT OF SET H2O TEMPERATURE
Set the boiler temperature from 65 - 80°C (set using keys 4 - 5). Press the
OK
key to display the temperature set; this can be modied using
the
OK
or
OK
keys.
The change must be conrmed by pressing the key
OK
.
PUMP OPERATION
The pump activates water circulation when the temperature of the water inside the stove reaches approx. 60°C. As the pump always functions
above 60°, it is recommended to keep a heating area open at all times to allow for uniform operation, preventing blocks due to overheating.
Normally this area is dened as the safety zone.
ROOM TEMPERATURE in the models envisioned)
IT IS possible to activate/deactivate the front ventilation and control the room temperature via the Room probe (integrated in the handheld
device). (See the chapter "ventilation" on the following pages.)
BURN POT CLEANING
During the working phase, the stove has an internal timer, which after a pre-set period of time cleans the burn pot.
This phase is shown on the display, it interrupts pellet loading and increases the fumes exhaust motor for a certain period of time. When the
cleaning phase is nished, the stove will re-start automatically and continue the working phase, returning to the selected power level.
MODULATION and H-OFF
As the water temperature approaches the set point, the boiler starts to modulate automatically bringing itself to the minimum power. If the
temperature increases beyond the set point, it will automatically switch o indicating HOFF and will automatically go back on when the
temperature drops below the set point.
SWITCHOFF
Press the
key for three seconds.
Once this operation has been performed, the appliance automatically enters the switch-o phase, blocking the supply of pellets.
The ue gas exhaust motor and the hot air ow motor will remain on until the stove temperature has dropped below the default
parameters.
REIGNITION
The stove can only be re-ignited automatically or manually when the cooling cycle conditions and the preset timer have been satised.
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Extraflame EVELYNE IDRO 2.0 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Extraflame EVELYNE IDRO 2.0 in the language / languages: English as an attachment in your email.

The manual is 10.18 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Extraflame EVELYNE IDRO 2.0

Extraflame EVELYNE IDRO 2.0 User Manual - German - 40 pages

Extraflame EVELYNE IDRO 2.0 User Manual - Dutch - 40 pages

Extraflame EVELYNE IDRO 2.0 User Manual - French - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info