23ENGLISH
SETTINGS
• DATETIME
• LANGUAGE
• DEGREES
See chapter: firSt ignition SettingS
DISPLAY
This menu allows you to adjust the brightness of the display. The values range from OFF, 1 to 20. If set to OFF, the display backlighting is set
to maximum brightness and turns o after a 60 second delay.
The backlighting can be turned on again by pressing any key or if the stove is in alarm status.
CONTROLS PROCEDURE
Press key 6.
Press key 3 until SETTINGS appears and conrm by pressing key 6.
Keep pressing key 3 until DISPLAY appears and conrm by pressing key 6.
Use keys 4-5 to set the desired intensity.
Press key 6 to conrm and key 1 to scroll back through the menus until the initial page.
STAND BY
The STAND BY function, if enabled, is used when stove switch-o is to be controlled by means of an additional thermostat
CONTROLS PROCEDURE
Press key 6.
Press key 3 until SETTINGS appears and conrm by pressing key 6.
Keep pressing key 3 until STAND BY appears and conrm by pressing key 6.
Use keys 4-5 to enable (ON) / disable (OFF).
Press key 6 to conrm and key 1 to scroll back through the menus until the initial page.
J
FOR CORRECT OPERATION, THE SET THERMOSTAT MUST BE SET TO LOWTA.
> SEE CHAPTER ON ADDITIONAL THERMOSTAT SETTINGS
STAND BY FUNCTION ON
If the STAND-BY function is active (ON), if the room temperature exceeds the value of the SET THERMOSTAT + DELTA T OFF, then the stove
will switch o after a preset delay, displaying STAND BY.
When the room temperature is lower than the SET THERMOSTAT - DELTA T ON and after a possible cooling time, the stove switches back on.
STAND BY FUNCTION OFF FACTORY SETTING
If the STAND-BY function is not active (OFF ), if the stove exceeds the set room temperature it will switch to the minimum value, modulating
and displaying MODULATION. When the room temperature is lower than the SET THERMOSTAT the stove goes back to operating at the set
power, displaying WORK.
OPERATION WITH ADDITIONAL THERMOSTAT OPTIONAL
STAND BY FUNCTION OFF FACTORY SETTING
If the STAND-BY function is not active (OFF ), if the stove exceeds the room temperature set on the additional thermostat (contact open) it will
switch to the minimum value, displaying MODULATION. When the room temperature is lower than the value set on the additional thermostat
(contact closed), the stove goes back to operating at the set power, displaying WORK.
STAND BY FUNCTION ON
When the STAND-BY function is active (ON), when the room temperature set on the additional thermostat has been reached (contact open),
the stove will switch o after a preset delay, displaying STAND BY.
When the room temperature is lower than the value set on the additional thermostat (contact closed) and after a possible cooling time, the
stove switches back on.
J
WHEN STAND BY AND AIR ZONE CONTROL ARE ACTIVE, THE GENERATOR IS SWITCHED OFF ONLY IF BOTH ROOMS
INSTALLATION, DUCTING REACH THE SET TEMPERATURE.
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Extraflame DAHIANA VFS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Extraflame DAHIANA VFS in the language / languages: English as an attachment in your email.

The manual is 11.02 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Extraflame DAHIANA VFS

Extraflame DAHIANA VFS User Manual - German - 36 pages

Extraflame DAHIANA VFS User Manual - Dutch - 36 pages

Extraflame DAHIANA VFS User Manual - French - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info