FIRST LOAD
This function allows you to activate the gearmotor for continuous pellet feeding.
Before starting the function, make sure the stove is cold and OFF”.
To set: OK > SETTINGS > FIRST LOAD
To stop continuous feeding, simply press and hold the key
OK
for 2 seconds.
QUICK ACCESS:
Before starting the function, make sure the stove is cold and OFF”.
Press keys
OK
+ at the same time for two seconds until the message "FIRST LOAD is displayed.
To stop continuous feeding, simply press and hold the key
OK
for 2 seconds.
DELTAT
This function allows the hysteresis thresholds to be set for stove ignition (DELTA-T ON) and switch-o (DELTA-T OFF), used as a room
temperature adjustment interval if not managed by an external thermostat.
The possible values of DELTA-T vary between 0.5 - 5 °C
To set: OK > SETTINGS > DELTAT
RESET
Allows the user to reset all editable values to the default values.
To set: OK > SETTINGS > RESET.
DEPRESSURE NOTICE
Allows the radio control buzzer to be activated for an acoustic warning if the door is opened.
Please note: Activation can reduce battery life by 30%.
The battery life depends on the usage
To set: OK > SETTINGS > DEPRESSURE NOTICE.
DELAY SWITCHOFF
You can program a delayed switch-o for the stove. For example, if it is 8 pm and the delayed switch-o is set to 1h, the stove will automatically
switch o at 9 pm.
If you press and hold keys
OK
+
OK
at the same time, the screen DELAY SWITCHOFF will appear (this setting can only be congured if
the stove is in the PREPARATION or WORKphase.
Use keys
OK
and
OK
to increase/decrease the number of hours after which the stove will automatically start the nal cleaning phase.
The number of hours range from OFF, 1 to 9.
Press P6 to conrm and return to the home page.
One hour after the set switch-o time, the remaining operating time is indicated by displaying at one-minute intervals “switch o in and
the time “HOURS xx:xx”.
ADDITIONAL FUNCTIONS
EASY CONTROL
The function allows for two values to be set:
OFF (disabled - factory default)
ON (enabled)
Activation (EASY CONTROL = ON) is recommended in the event that there is an excessive formation of combustion residues in the ue
during operation at reduced power (see FLUE EXHAUST chapter).
Caution! It is advisable to activate the EASY CONTROL function under the supervision of a qualied technician.
To set: OK > SETTINGS > EASY CONTROL
32


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Extraflame Comfort P85 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Extraflame Comfort P85 in the language / languages: English as an attachment in your email.

The manual is 11.43 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Extraflame Comfort P85

Extraflame Comfort P85 User Manual - German - 40 pages

Extraflame Comfort P85 User Manual - Dutch - 40 pages

Extraflame Comfort P85 User Manual - French - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info