811717
28
Zoom out
Zoom in
Previous page
1/40
Next page
28 ENGLISH
FRONT AIR
This menu allows the front ventilation motor speed to be set. Range: (COMFORT, AUTO).
If COMFORT mode is selected, the front air speed is reduced.
In order to optimise the performance of the appliance at minimum power, front ventilation can be excluded automatically
To set: OK > FRONT AIR >SET
EASY SETUP
The volumetric weight of the pellet is the ratio between the weight and the volume of the pellet. This ratio may change without altering
pellet quality. By using the EASY SETUP function, it is possible to dose the pellets by increasing or decreasing the preset values.
In the stove program, the available values range from “– 3” to “+ 3”; all stoves are calibrated during production with the optimal value which
is 0
If you notice an excessive deposit on the burn pot, access the EASY SETUP program and lower the value by one unit to “- 1”; then wait until
the next day and if there is no improvement, decrease again, to a maximum of “- 3”. If, on the other hand, it is necessary to increase the pellet
dosage, switch the factory value from "0" to "+ 1, + 2, + 3" as required.
To set: OK > EASY SETUP
EXCESSIVE PELLET DEPOSIT IN BURN POT NORMAL OPERATION MINIMUM PELLET DEPOSIT IN BURN POT
-3 -2 -1 0 +1 +2 +3
THIRD DECREASE
RANGE IF THE
FIRST TWO ARE
INSUFFICIENT
SECOND
DECREASE
RANGE IF
THE FIRST IS
INSUFFICIENT
FIRST DECREASE
RANGE (TEST FOR
1 DAY )
OPTIMAL FACTORY
VALUE
FIRST INCREASE
RANGE
SECOND
INCREASE RANGE
IF THE FIRST IS
INSUFFICIENT
THIRD INCREASE
RANGE IF THE
FIRST TWO ARE
INSUFFICIENT
N.B.: IF THESE ADJUSTMENTS DO NOT SOLVE THE PROBLEM OF PELLET DEPOSITS IN THE BURN POT, PLEASE CONTACT YOUR LOCAL
SERVICE CENTRE.
AIR DUCTING 1 P85 PLUS ONLY
This menu allows a choice of two operating modes for air ducting 1, and the regulation of the set temperature if an NTC probe is connected
in input: AUTO - COMFORT
To set: OK > AIR DUCTING 1 > SET
To adjust the temperature: OK > AIR DUCTING 2 > TEMPERATURE
AIR DUCTING 2 P85 PLUS ONLY
This menu allows a choice of two operating modes for air ducting 2, and the regulation of the set temperature if an NTC probe is connected
in input: AUTO - COMFORT
To set: OK > AIR DUCTING 2 > SET
To adjust the temperature: OK > AIR DUCTING 2 > TEMPERATURE
MODES
This menu allows you to set the machine operation logic. Range: (AUTOMATIC, SELF CONTROL)
If AUTOMATIC mode is selected, the stove power will be automatically adjusted to reach the set temperature without exceeding it.
This function improves the experience of using the generator in terms of consumption, thermal and acoustic comfort and the
reduction in the need for cleaning and maintenance.
If SELF CONTROL mode is selected, the stove will heat the room to the set temperature whilst maintaining the power set by the user.
To set: OK > MODE > SET
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Extraflame Comfort P85 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Extraflame Comfort P85 in the language / languages: English as an attachment in your email.

The manual is 11.43 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Extraflame Comfort P85

Extraflame Comfort P85 User Manual - German - 40 pages

Extraflame Comfort P85 User Manual - Dutch - 40 pages

Extraflame Comfort P85 User Manual - French - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info