IGNITION
Once the previously listed points have been checked, press key
OK
for three seconds to ignite the stove.
15 minutes are available for the ignition phase. After ignition and after reaching the control temperature, the
stove interrupts the ignition phase and switches to STARTUP.
STARTING
During the start-up phase, the stove stabilises combustion, increasing it progressively, to then start ventilation and switch to WORK.
WORK
During the work phase, the stove will function at the set power and work to reach the set room temperature. See next heading.
REGULATION OF SET THERMOSTAT
When the key
OK
is pressed, the set temperature is viewed; it can be changed using keys
OK
or
from LOWTA-07 to 40°C - HOT.
The change must be confirmed by pressing the key
OK
.
LOWTA  HOT
If the temperature is set at "LOWTA" (set below the limit of 7°C), the stove will always run at minimum.
If the setting is on "HOT" (set above the limit of 40°C) the stove will not modulate, running only and always at the set power.
REGULATION OF SET POWER
The set power has 5 operating levels, When key
OK
is pressed, the set power is displayed; it can be changed using keys
or
.
Power 1 = minimum level - Power 5 = maximum level.
The change must be confirmed by pressing the key
OK
.
WORKING WITH ROOM PROBE STANDARD
The appliance monitors the room temperature using a probe incorporated into the handheld.
Once the set temperature has been reached, it will automatically switch to the minimum power level or turn o, activating the STANDBY
function, reducing pellet consumption to a minimum.
By factory default, the STBY function is always set to OFF.
For information on its activation and logic, follow the instructions on the next page, chapter: STANDBY.
BURN POT CLEANING
During the working phase, the stove has an internal timer, which after a pre-set period of time cleans the burn pot.
This phase is shown on the display, it lowers the stove power level and increases the ue gas exhaust motor for a programmed period of time.
When the cleaning phase is nished, the stove will re-start automatically and continue the working phase, returning to the selected power
level.
SWITCHOFF
Press the key
OK
for three seconds.
Once this operation has been performed, the appliance automatically enters the switch-o phase, blocking the supply of pellets.
The ue gas exhaust motor and the hot air ow motor will remain on until the stove temperature has dropped below the default
parameters.
REIGNITION
- The sTove can be re-igniTed only if The flue gas TemperaTure has lowered, and if The pre-seT Timer has been reseT.
OPERATION AND LOGIC
17
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Extraflame Anastasia Plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Extraflame Anastasia Plus in the language / languages: English as an attachment in your email.

The manual is 5,86 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Extraflame Anastasia Plus

Extraflame Anastasia Plus User Manual - German - 36 pages

Extraflame Anastasia Plus User Manual - Dutch - 36 pages

Extraflame Anastasia Plus User Manual - French - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info