783561
14
Zoom out
Zoom in
Previous page
1/71
Next page
CARAT
14
Additional handling of the machine
Changing the group gasket
CLEANING AND CARE
Remove and insert the porta-filter gently.
Never use excessive force to try to close the
porta-filter.
To remove the porta-filter, use a
straight-blade screwdriver to release
the shower by prying down with
medium force.
Remove the filter basket(A), then
place the new gasket and shower(B)
into the porta-filter(C).
Remove the shower and gasket.
Preheat the gasket to soften the rubber. A - heat the gasket for 15 seconds
using the water from the hot water outlet, or B - place the gasket, shower,
and porta-filter in hot water for 30 seconds.
Remove and discard the old gasket.
Insert the new gasket (chamfer and
EXPOBAR logo facing up) into the
shower.
Important:
Avoid placing wet cups directly on the
cup shelf, it may drip into the machine
and cause machine damage.
01
04
02
05
03
15s
30s
99 OC
A
A
B
C
B
> 65 OC
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Expobar Carat at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Expobar Carat in the language / languages: English as an attachment in your email.

The manual is 12.79 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info