6. Install station
6.1 Safety requirements
Connecting and installing this product must be done by a qualied electrician. The owner or
facility manager is responsible for the installation, operation, and maintenance of the charging station,
whereby both the law regarding the safety of persons, animals, and property must be observed, as well
as the installation instructions enforced in the country of use.
Read the safety instructions before you start work on the installation.
Ensure the correct supply voltage/power and ensure that the meter cabinet is properly secured.
The charging station complies with Safety Class I (the charging station is supplied with a ground
terminal for safety) and overvoltage Category III. The charging station complies with Safety Class I
(ground terminal safety) and Category III (overvoltage).
The incoming and/or outgoing terminals for the alternating current are tted with an
uninterruptible grounding for safety. If it is possible that the ground safety has been damaged, the
charging station must be taken out of operation and secured against accidental activation.
Each charging station must be protected by a residual current device (Type A-EV or Type B)
with direct current fault detection of >6 mA DC. The residual current device must disconnect
all the phases connected and the “Neutral”. The applied RCD must comply with local law and
regulations.
Before switching on the charging station, check that the power source available corresponds
to the conguration settings of the charging station as described in this manual and that all the
cables inside the charging station have been properly connected.
Make sure that the product is only used under the correct operating conditions (refer to chapter
“4. Technical specications”).
Never operate the charging station in wet or very dusty surroundings.
Planning the installation
Minimum requirements
Make sure that each side of the unit is connected to its own dedicated power line, except for
models BXXX2-X20XX (which must be powered by a 1 x 32A rated power cable).
Calculate the existing electrical load to nd the maximum operating current.
Calculate the distance to ensure minimal voltage drop.
Obtain any necessary permits from the local authority that has jurisdiction and make sure to
schedule the follow-up inspection with a qualied and licensed electrician after the installation is
complete.
Use only copper conductors.
Refer to local wiring regulations to select the conductor sizes.
Ensure that there is always adequate free space (at least 20 cm) around the charging station for
ventilation purposes.
Use appropriate tools and provide resources and protection measures.
EN
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for EVBox BusinessLine at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of EVBox BusinessLine in the language / languages: English as an attachment in your email.

The manual is 0.42 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of EVBox BusinessLine

EVBox BusinessLine User Manual - English, German - 44 pages

EVBox BusinessLine Usermanual and installation guide - Dutch - 46 pages

EVBox BusinessLine User Manual - Dutch, French, Italian, Portuguese, Swedish, Spanish, Norwegian - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info