When transporting do not position the product horizontally. Unloading of the product must be performed using suitable lifting means and that have characteristics
that comply with the weight of the stove. The operator must make sure that during offloading and lifting of the stove there are no persons or objects nearby. When
unpacking, avoid damaging the product with cutters or blunt tools. Keep the packaging out of reach of children. Unscrew the screws that secure it to the pallet from
below and place the stove in the dedicated position paying attention to any obstructions that may hinder installation or damage the item.
STOVE INSTALLATION
In compliance with the current regulations for installation, the stove must be installed in a ventilated place with air that is sufficient to ensure correct combustion
and therefore good operation. The room must have a volume no less than 20 m3. In order to ensure good combustion (40m3/h of air) there must be a “combustion
air intake” that reaches an external wall or a wall of an adjacent room with an external air intake (Ø 80mm minimum diameter). The adjacent room must not be a
bedroom or bathroom, or contain any fire risks, such as storerooms, garages, combustible materials stores, etc. These air intakes must be made in such a way as
to avoid being blocked internally or externally, and should be covered with a grille, metal mesh or suitable protection, as long as the minimum diameter is not
reduced.
The stove must not be positioned close to curtains, armchairs, furniture or to other flammable materials.
The stove must not be installed in explosive or potentially explosive environments which may become explosive due to the presence of machinery, materials or
dust that can cause greenhouse gas emissions or which can easily ignite with sparks. Before preparing to install the pellet stove, bear in mind that all finishes or
any beams made of flammable material must be positioned at a safe distance outside the area of irradiation of the stove itself. Bear in mind also that to in order
not to compromise correct operation of the appliance, a recirculation of air inside its housing must be created, which will prevent overheating. This is possible by
respecting minimum distances and by creating ventilation holes.
The fume outlet can be located on the upper side or on the rear side of the stove. You can decide between the rear and the top fume outlet based on the location
of the vent pipe.
THE STOVE DOES NOT WORK IF THE LID OF THE PELLET HOPPER IS OPEN.
02.3 ELECTRICAL CONNECTION
The electrical connection must be performed by qualified personnel who install circuit breakers upstream of the appliance.
Special attention should be paid when the operation is a supplementary action and all equipment must operate as planned.
Avoid installations with electric cables that run close to fume pipes or hot components that are suitably insulated.
The voltage is 230 V while the frequency is 50 Hz.
The electrical system, at the connection point, must be have a ground connection as required by EEC Regulation 73/23 and EEC 93/98.
02.4 EXTERNAL THERMOSTAT
In this product it is possible to install an external thermostat. This operation may only be performed by authorised personnel. Use a 2-pole cable with everyday
double insulation. Connect the two pins to the connector of the CN7 electronic board pins 7-8. Enabling the external thermostat by bringing to room temperature,
T-ON will be present when the thermostat prompts and T-OF when the thermostat is satisfied. If the thermostat is closed, the appliance works at the set heat output.
If the thermostat is activated, the appliance will work in the MODULAT- state until it is switched off; if it is on STAND-BY, it is active.
02.5 DUCTING TREVISI ONLY
Ducting can be used on the Trevisi model. To channel the air, break the pre-cut for at the back. An 80-mm pipe must be used. Ducting disabled is the factory
default. If no ducting is installed, the control on the remote control must be kept in the OFF position. This will prevent the stove from overheating.
Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.
Product:
Forumrules
To achieve meaningful questions, we apply the following rules:
First, read the manual;
Check if your question has been asked previously;
Try to ask your question as clearly as possible;
Did you already try to solve the problem? Please mention this;
Is your problem solved by a visitor then let him/her know in this forum;
To give a response to a question or answer, do not use this form but click on the button 'reply to this question';
Your question will be posted here and emailed to our subscribers. Therefore, avoid filling in personal details.
Register
Register getting emails for Eva Calor TREVISI at:
new questions and answers
new manuals
You will receive an email to register for one or both of the options.
Get your user manual by e-mail
Enter your email address to receive the manual of Eva Calor TREVISI in the language / languages: English as an attachment in your email.
The manual is 3.64 mb in size.
You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.
The manual is sent by email. Check your email
If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.
The email address you have provided is not correct.
Please check the email address and correct it.
Your question is posted on this page
Would you like to receive an email when new answers and questions are posted? Please enter your email address.