14. EV STOVE ALARMS
In the event of a malfunction, the control board indicates the problem and activates various procedures depending on the type of alarm. The possible alarm
messages are listed below:
Display shows No. Cause
WATER SENSOR ALARM (AL C) Water probe broken or shorted
HOT WATER ALARM (AL D) Stove water maximum threshold exceeded
WATER PRESS ALARM (AL E) Water pressure too low or too high
FUME SENSOR ALARM (2) Fume temperature probe fault
HOT FUME ALARM (3) Fume overheating
EXTRACTION FAULT ALARM (4) Exhaust blower fault, not working
IGNITION FAULT ALARM (5) Stove does not ignite
NO PELLET ALARM (6) Shutting down due to insufficient pellets
THERMAL/DOOR SAFETY ALARM (7) Safety thermostat tripped or door not completely closed
NO NEG. PRESS ALARM (8) Depressor activated
AUGER TUBE ENCODER ALARM (AL G) Faulty auger tube encoder
AUGER TRIAC ERROR ALARM (AL B) The auger tube turns continuously
CLEANER FAULT ALARM (AL E) The burn pot cleaner is blocked
ALARM TURBULATOR FAULT (AL F) Turbulator cleaning is blocked
POWER OUTAGE ALARM (1)
Absence of mains voltage
In case of alarm, the stove is immediately switched off.
The alarm status can be reset by pressing the P4 button.
Safety thermostat
If the safety thermostat detects a water temperature exceeding the trigger threshold, it immediately switches off the
auger tube (to which it is connected in series), while acquiring this change in status via the AL1 terminal on CN4.
The message THERMAL SAFETY ALARM appears on the display and the system is switched off. Unscrew the
black cap on the back of the stove and press the button to reset the contact.
Negative pressure alarm
This alarm occurs if:
The flue pipe is non-compliant: the pipe must minimise the pressure in Pascals required by the manufacturer (see TECHNICAL DATA) at both low and
maximum heat output;
The flue pipe or combustion air intake is blocked.
The door of the combustion chamber and/or the door of the pellet tank are open.
Excessive dirt inside fume circulation area: empty the ash that is deposited in the part adjacent to the ash drawer compartment.
Damage exhaust blower alarm
In case the fume extraction fan breaks, the stove switches off and the message EXTRACTION FAULT ALARM is displayed
Power outage alarm
In the event that there is an electrical power failure for a given time, the stove, with restoring of the electricity, will change to BLACK-OUT alarm. It is necessary to
wait for the stove to cool down and then turn it back on.
32


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Eva Calor Tosca at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Eva Calor Tosca in the language / languages: English as an attachment in your email.

The manual is 4.77 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Eva Calor Tosca

Eva Calor Tosca User Manual - German - 43 pages

Eva Calor Tosca User Manual - Dutch - 43 pages

Eva Calor Tosca User Manual - French - 43 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info