When in programming mode, use this button to modify/increase the selected menu value. When in working mode/switched off, use instead this button to increase
the stove temperature value.
BUTTON 2 (P2) - Temperature decrease:
When in programming mode, use this button to modify/decrease the selected menu value. When in working mode/switched off, use this button to decrease the
room thermostat temperature value.
BUTTON 3 (P3) – Set/menu:
Use this button to access the temperature setting and user and technician parameter menu. After entering the menu, use this button to access the next sub-menu
or set the value and move to the next menu item when in programming mode.
BUTTON 4 (P4) – ON/OFF release:
Hold this button down for two seconds to manually switch the stove on or off respectively depending on its initial status (switched on or off). If alarms have occurred
which have caused the stove to lock, the button allows unlocking and subsequent passage to the off state. After accessing the menu or during the programming
phase, use this button to access the upper menu level. Any changes are automatically saved.
BUTTON 5 (P5) - Heat output decrease:
When in working mode, use this button to decrease the heat output value. In menu mode, use this button to move to the next menu item or, in programming mode,
to go back to the subsequent sub-menu item. Any change is automatically saved.
Fan speed setting: by pressing button 5 it is possible to adjust the room ventilation speed (IF PRESENT).
BUTTON 6 (P6) - Heat output increase:
When in working mode, use this button to modify the exchanger speed. In menu mode, use this button to go back to the previous menu item or, in programming
mode, to go back to the previous sub-menu item. Any change is automatically saved.
08.2 MENU
Press P3 (menu) to access the menu.
It includes several items and levels to access settings and control board programming.
The menu items providing access to the technical setting are protected by access code.
USER MENU
The table below briefly describes the menu structure, focusing in particular on the functions available to users.
The menu item 01-fan adjustment is available only if the corresponding function was enabled.
Menu 01 – SET CLOCK
Use this function to set current time and date. The control board is equipped with a lithium battery guaranteeing the internal time clock a 3/5 year-long life.
Menu 02 – SET CHRONO
Submenu 02 – 01 – ENABLE CHRONO
Allows every chrono-thermostat function to be enabled or disabled.
Submenu 02 - 02 – DAILY PROGRAM
The daily programmable chrono-thermostat functions can be enabled, disabled and set.
Submenu 02 - 03 – WEEKLY PROGRAM
The weekly programmable chrono-thermostat functions can be enabled, disabled and set. The weekly programmer has 4 independent programs whose
final effect involves the combination of the 4 individual programs. The weekly programmer can be enabled or disabled. Moreover, if the time is set to
OFF, the time clock ignores the corresponding control.
Caution: perform the programming carefully avoiding generally overlapping of the activation and/or deactivation hours on the same day in different
programs.
Submenu 02 - 04 – PROGRAM WEEK-END
The programmable chrono-thermostat functions can be enabled, disabled and set for the week-end (days 5 and 6, or Saturday and Sunday).
SUGGESTION: if you still do not know exactly the result you want to obtain, enable only one programme at a time to avoid confusion and unwanted
stove switching on and off.
Disable the daily programme if you want to use the weekly programme. If you use the weekly programme for 1, 2, 3 and 4 programmes, never enable
the week-end programme.
Always disable the weekly programme before enabling the week-end programme.
Menu 03 - SELECT LANGUAGE
Use this command to select one of the languages available.
Menu 04 - CHOOSE SEASON
Menu 04 - STAND-BY MODE - ACTIVATE DEFAULT MODE 2
If you select the “STAND-BY” mode, the stove switches off after a period of time, set by Pr44, during which the room temperature remains at a value higher than
the SET temperature.
Only if the following condition occurs it is then possible to switch the stove back on:
TSET < (Tstove-Pr43)
FOR THE INSTALLER:
There are 3 standby modes:
Mode 1
WITH RESPECT TO THE AMBIENT PROBE AND THE TEMPERATURE OF THE WATER.
Having set the water temperature, commence operation of the stove.
1- With the room set reached, the stove goes into stand-by
2- With the air set not reached, the stove is working.
Nearing Set Water, the stove goes into modulation and remains in modulation.
It goes into STAND-BY only when the air set is reached.
It comes back on when the stove falls beneath the air set.
The room probe has priority.
Mode 2
WITH RESPECT ONLY TO THE WATER TEMPERATURE
Having set the water temperature, commence operation of the stove.
Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.
Product:
Forumrules
To achieve meaningful questions, we apply the following rules:
First, read the manual;
Check if your question has been asked previously;
Try to ask your question as clearly as possible;
Did you already try to solve the problem? Please mention this;
Is your problem solved by a visitor then let him/her know in this forum;
To give a response to a question or answer, do not use this form but click on the button 'reply to this question';
Your question will be posted here and emailed to our subscribers. Therefore, avoid filling in personal details.
Register
Register getting emails for Eva Calor Tosca at:
new questions and answers
new manuals
You will receive an email to register for one or both of the options.
Get your user manual by e-mail
Enter your email address to receive the manual of Eva Calor Tosca in the language / languages: English as an attachment in your email.
The manual is 4.77 mb in size.
You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.
If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.
The email address you have provided is not correct.
Please check the email address and correct it.
Your question is posted on this page
Would you like to receive an email when new answers and questions are posted? Please enter your email address.