668822
37
Zoom out
Zoom in
Previous page
1/47
Next page
36
04. PRODUCT USE
Alarms
In case of malfunctioning the control board reports the problem and activates various procedures depending on the type of alarm.
Possible alarm messages are listed below.
Cause
Display shows
Fume temperature sensor
ALARM FUME SENSOR
Fume overheating
ALARM HOT TEMP
Ignition failure
ALARM NO FIRE
Switches off when in working mode
ALARM NO FIRE
Power outage
COOL FIRE (see sect. 9.2)
Auger tube safety pressure switch
ALARM PRESS FAIL
General safety thermostat
ALARM SAFETY FAIL
Damaged exhaust blower
ALARM FAN FAIL
In case of alarm, the stove is immediately switched off.
The alarm status is reached after a set period of time (Pr11) and can be cleared by pressing the P4 button.
Fume temperature sensor alarm
The alarm is triggered when the fume temperature sensor is not working properly or is disconnected. During the alarm, the stove
switches off.
fig. 27
Fume overtemperature alarm
The alarm is triggered when the fume sensor identifies a temperature exceeding 280°C. The message shown in figure 28 appears.
fig. 28
The stove switching-off phase starts immediately.
Ignition failure alarm
The alarm is triggered whenever ignition fails. The stove switching-off phase starts immediately.
fig. 29
37


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Eva Calor Tosca 24 kW at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Eva Calor Tosca 24 kW in the language / languages: English as an attachment in your email.

The manual is 4,1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Eva Calor Tosca 24 kW

Eva Calor Tosca 24 kW User Manual - German - 38 pages

Eva Calor Tosca 24 kW User Manual - Dutch - 90 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info