11.3.8 Timer ON 2 switching on 2 hours minutes
Press button 2 and then button 8 repeatedly to select UT08.
Press then statuses 1 and 2
to set timer hours and minutes. Upon finishing, press button 8 repeatedly to exit the technical menu or wait
20 seconds.
11.3.9 Timer OFF 2 switching off 2 hours minutes
Press button 2 and then button 8 repeatedly to select UT09. Press then statuses 1 and 2
to set timer hours and minutes. Upon finishing, press button 8 repeatedly to exit the technical menu or wait
20 seconds.
11.3.10 Enabling Timer 2
Press button 2 and then button 8 repeatedly to select UT10. Press then statuses 1 and 2
to enable (On) or disable (Off) the timer. LED 3 switches on upon completing timer enabling.
Upon finishing, press button 8 repeatedly to exit the technical menu or wait 20 seconds.
11.3.11 Parameter percentage adjustment
The pellet load and fume exhaustion percentages can be modified using parameter Cpel and Casp respectively:
• CASP is the fume exhaustion percentage variation.
• CPEL is the pellet load percentage variation. Modify the parameters as follows:
• Enter the UT04 technical menu.
•Press buttons 1 and 2 repeatedly until the display shows “c9”. Hold the buttons down to move more
rapidly.
• Press button
8 to confirm.
• Press button
8 to select Cpel or Casp.
• Press buttons 1
and 2 to modify the value.
• Cpel and Casp values range from -5 to +5. Each step corresponds to a variation equal to ± 5 %.
with respect to the basic value. (PR06 ÷ PR10 for pellet loading and PR18 ÷ PR22 for fume exhaust blower).
• The default values are:
Cpel = 0 Casp = 0
11.4.Alarms
11.4.1 “NO ACC” alarm.
The alarm is triggered when the fume temperature does not increase by a gradient equal to 3
°
C/min
during the LOAD
WOOD or FIRE ON phases and does not reach the temperature set by PR13 within the time set by PR01:
• The switching-on phase is interrupted and the stove switches off.
• The display shows the message “ALAR/ No/
A
cc
”.
• Use the control panel or remote control to clear the alarm (hold on/off button down for at least 2 seconds).
11.4.2 “NO FIRE” alarm.
If the stove switches off during the working mode (the fume temperature reaches a value below the PR13 parameter), the
stove enters the switching-off phase.
• The display shows the message “ALAR/No/Fire”.
• Use the control panel or remote control to clear the alarm (hold on/off button down for at least 2 seconds).