643343
3
Zoom out
Zoom in
Previous page
1/44
Next page
1.Safety warnings
Installation and connection must be carried out by qualified staff in compliance with local regulations, national and
European standards (UNI 10683) and with the installation instructions contained herein. The electrical system of the
room where the stove is to be installed must comply with current regulations.
The combustion of waste, especially of plastic materials, damages the stove and the vent pipe. Moreover, it is
forbidden by the law against the emission of harmful substances.
Do not use alcohol, petrol or other highly inflammable liquids to light the fire or poke it during operation.
EVA CALOR stoves are manufactured in compliance with:
89/106/EC Directive (Construction products);
2006/95/EC Directive (Low voltage);
2004/108/EC Directive (Electromagnetic Compatibility).
The harmonised standards or the technical specifications (designations) applied according to the
current European safety rules are:
2.Installation instructions
Follow the instructions below before installing your stove.
Select the position where the stove is to be installed and:
Arrange the connection to the vent pipe for fume extraction
Arrange the external air intake (combustion air)
Arrange the connection to the earthed mains
The electical system of the room where the stove is to be installed must be earthed, otherwise the control board may
not work properly.
Place the stove on the floor in a convenient position for the connection to the vent pipe and close to the combustion
air intake.
The appliance must be installed on a floor with an adequate loading-bearing capacity.
Should the existing floor not comply with the requirement above, proper measures must be taken (for instance, the
installation of a load distribution plate).
All the structures which can catch fire if exposed to excessive heat must be protected. Floors made from wood or
inflammable materials must be protected using non-combustible materials (e.g. 4mm-thick sheet metal or ceramic glass).
The appliance installation must ensure easy access for cleaning the stove, exhaust pipes and vent pipe.
This appliance is not suitable to be installed on a shared vent pipe.
During normal operation, the stove draws air from the room where it is installed. Therefore, an external air intake
must be positioned at the same height of the pipe located on the stove back. Exhaust fume pipes must be suitable for
pellet stoves and therefore made from coated steel or stainless steel, with a diameter of 8cm and fitted with adequate
gaskets.
The combustion air intake (
Φ
80mm) must be connected directly to the outside or to adjacent rooms provided they are
fitted with external air supply vents (
Φ
80mm) and are not used as bedrooms or bathrooms or, whenever a fire hazard exists,
as storage rooms, garages, combustible material warehouses, etc. The air vents must be placed in such a way that they
cannot be clogged either from the outside or inside and must be protected using a grille, a metal mesh or other suitable
means provided they do not reduce the minimum section.
Standards or other reference rules
EN 14785
EN 60335-1
EN 60335-2-102
EN 55014-1
EN 61 000-3-2
EN 55014-2
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Eva Calor SPV-M11 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Eva Calor SPV-M11 in the language / languages: English as an attachment in your email.

The manual is 2,15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Eva Calor SPV-M11

Eva Calor SPV-M11 Usermanual and installation guide - Dutch - 90 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info