643345
15
Zoom out
Zoom in
Previous page
1/44
Next page
When the set room temperature value is reached, the stove heat output is automatically set to the minimum value.
ECO (Economy) message appears on the upper display and the room thermostat LED switches on. The Auger tube motor
stops and the exhaust blower speed increases. The exchanger blower remains on until the fume temperature reaches
a value below the preset PR15 value. The exhaust blower switches off after approx. 10 minutes. Depending on the
version, it may be necessary to wait the period of time set by Pr73 parameter before switching on the stove
again. During the wait, P4 button is inactive and the following message appears asking users to wait until
the end of the switching off phase.
The same happens whenever the fume temperature exceeds the maximum value set by Pr14 parameter. Once the
temperature falls again within the set range, the stove goes back to the normal working mode.
9.4.8 Burn pot cleaning
When the stove is in the normal working mode, theBURN POT CLEANING” mode is activated for the period set by Pr12
parameter at the intervals set by Pr03 parameter.
9.4.9 Programmable thermostat
The programmable thermostat function allows for the programming of the stove automatic switching on and off
during the week.
Press P3 button twice to enter the programming mode. Press P3 button again to cycle through all
the parameters available. Press instead P4 button to exit the programming at any time. The
programmable thermostat parameters are listed below:
Parameter
Description
Available values
UT01
Current day setting and programmable thermostat
enabling/disabling
Day1,...Day7; OFF;
UT02
Current time setting
from 00 to 11
UT03
Current time minute setting
From 00 to 60
UT04
ONLY FOR TECHNICIANS – DO NOT enter any setting
From 00 to P5
UT05
PROGRAMME 1 switching on time setting
From 00:00 to 11:50 pm by
10’ steps
UT06
PROGRAMME 1 switching off time setting
From 00:00 to 11:50 pm by
10’ steps
UT07
Day selection with stove switching on according to
PROGRAMME 1
On/off for days from 1 to 7
UT08
PROGRAMME 2 switching on time setting
From 00:00 to 11:50 pm by
10’ steps
UT09
PROGRAMME 2 switching off time setting
From 00:00 to 11:50 pm by
10’ steps
UT10
Day selection with stove switching on according to
PROGRAMME 2
On/off for days from 1 to 7
Some parameters are described in detail below:
UT01
Press P1 and P2 buttons to enable the programmable
thermostat.
Then set the current week day.
(Day 7 = Sunday).
Press P1 and P2 buttons and then select OFF to disable
the programmable thermostat.
D1 Display
Meaning
Day 1
Monday
Day 2
Tuesday
Day 3
Wednesday
Day 4
Thursday
Day 5
Friday
Day 6
Saturday
Day 7
Sunday
OFF
Programmable thermostat
disabled
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Eva Calor SPCT 7.5 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Eva Calor SPCT 7.5 in the language / languages: English as an attachment in your email.

The manual is 2,15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Eva Calor SPCT 7.5

Eva Calor SPCT 7.5 Usermanual and installation guide - Dutch - 90 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info