Store pellets in a cool and dry place. Storing pellets in a damp or too cold place may reduce the stove potential
heat output. Be careful when storing and handling pellet bags to prevent pellet crushing and sawdust
production.
Clean the burn pot on a regular basis upon every ignition or pellet refuelling.
Open the firebox only upon refuelling or removal of residues to prevent fumes from escaping.
Do not switch the stove on and off intermittently to avoid damaging its electrical and electronic components.
Do not use the appliance as waste incinerator or for any other purpose other than the intended one.
Do not use liquid fuels.
Do not modify the appliance without prior authorisation.
Use only original spare parts recommended by the manufacturer.
The fuel consists of small cylinders with 6-7mm diameter and a maximum length of 30mm. Their maximum moisture
content is equal to 8%. This stove is designed to burn pellets made of compacted sawdust obtained from different types of
wood, in compliance with environment protection legislation.
The use of different types of pellets may result in a slight, sometimes even undetectable, change in the stove efficiency.
This change can be counterbalanced by increasing or decreasing the stove heat output by only one step.
Make sure that the stove is transported in compliance with safety regulations. Avoid any improper transfers or knocks
that may damage the ceramics or the structure.
The metal structure is coated using high temperature paints. When switching on the stove for the first times,
unpleasant odours may be emitted as the paint starts to harden on the metal parts. The fumes emitted are not
harmful. Ventilate the room to evacuate them. After the first heating cycles, the paint will reach its maximum adhesion
and all its chemical and physical features.
The hopper can contain up to 15 kg of pellets. Open the lid and pour the pellets to load it, also during normal
operation, making sure that no pellets fall out of it. Always refuel the hopper before leaving the operating stove
unattended for long periods of time.
Whenever the hopper and the Auger tube get completely empty, the appliance will be automatically switched off. It may
take two separate ignitions to resume operation at ideal working conditions since the Auger tube is very long.
CAUTION! If the stove is not properly installed, power outages may result in fume spillages.
Under specific circumstances, an uninterrupted power supply unit must be installed.
CAUTION!
Being a heating appliance, some parts of the stove can become extremely hot. We therefore recommend
paying special attention during operation.
WHEN THE STOVE IS WORKING:
do not open the door;
do not touch the door glass since it becomes extremely hot;
keep children away from it;
do not touch the fume outlet;
do not pour any liquid inside the firebox;
do not perform any maintenance operations if the stove is not cold;
only qualified technicians are allowed to perform any operation;
follow all the instructions contained herein.
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Eva Calor SPCT 7.5 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Eva Calor SPCT 7.5 in the language / languages: English as an attachment in your email.

The manual is 2,15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Eva Calor SPCT 7.5

Eva Calor SPCT 7.5 Usermanual and installation guide - Dutch - 90 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info