814229
4
Zoom out
Zoom in
Previous page
1/43
Next page
3
01. PRODUCT SAFETY
SAFETY WARNINGS
The stoves were built in compliance according to standard EN13240 (wood stoves), EN 14785 (pellet stoves) and EN 12815 (kitchens and wood-burning
stoves)using high quality and non-polluting materials. To make better use of your stove it is advisable to follow the instructions in this booklet.
Read this manual carefully before use or any maintenance operation.
Eva Stampaggi aims to provide as much information as possible to ensure safer use and to avoid damage to persons, property or parts of the stove itself.
Each stove is subjected to internal testing before shipment and as such residues inside the appliance may be found.
KEEP THE INSTRUCTION MANUAL FOR FUTURE REFERENCE
FOR ANY REQUIREMENT OR CLARIFICATION PLEASE CONTACT
THE AUTHORISED DEALER
The burning of waste, in particular plastic materials, damages the stove or stove and the flue, and is also prohibited by the law against emissions of harmful
substances.
Do not use alcohol, petrol or other highly inflammable liquids to light the fire or poke it during operation.
Do not introduce into the stove an amount of fuel greater than that recommended in this manual.
Do not modify the product.
It is forbidden to use the product with the door open or with broken glass.
Do not use the appliance such as a clothesline, support surface or ladder etc.
Do not install the stove in bedrooms or bathrooms if not certified as watertight.
The pellets to be used are the following:
The pellet stoves operate exclusively with pellets made from various types of legislative-compliant wood.
DIN plus or EN plus 14961-2 A1 or PEFC/04-31-0220 ONORM M7135, or having the following specifications:
Min. calorific heat output 4.8 kWh/kg (4180 kcal/kg)
Density 630-700 kg/m3
Maximum humidity 10% of weight
Diameter: 6 ±0.5 mm
Ash percentage: max. 1% of weight
Length: min. 6mm - max. 30mm
Composition: 100% untreated wood from the industry of wood or post-consumption without the addition of binders, bark-free and compliant with current
regulations.
02. GENERAL SAFETY PRECAUTIONS
Use the stove only as described in this manual. Any other use not recommended by the manufacturer may cause fires or accidents to people.
Make sure that the electrical power available corresponds to the value indicated on the data plate (230V~/50Hz).
This appliance is not a toy. Ensure children are not left unattended and do not use the appliance as a toy.
This device is not intended for use by persons (including children) with reduced physical or mental capacity, or without specific experience and knowledge,
unless supervised or duly instructed on the use of the appliance by a person responsible for their safety.
Disconnect the appliance from the mains when not in use or during cleaning operations.
To do so, turn the switch to the O position and disconnect the plug from the socket. Pull the plug, not the cable.
Never block the combustion air inlets and fume outlets.
Do not touch the stove with wet hands; it contains electrical components.
Do not use the appliance with damaged cables or plugs. The device is classified as type Y: the power supply cable may only be replaced by a
qualified technician. Should the power supply cable be damaged, it can be replaced only by the manufacturer or by its technical assistance service
or by a similarly qualified person.
Do not place any object on the cable and do not bend it.
Avoid using extension cables as their temperature may increase excessively posing fire hazards. Never use one single extension cable to power several
appliances.
During normal functioning some parts of the stove may become extremely hot, such as the door, the glass or the handle. Be careful, especially with
children. Do not touch any hot parts if not wearing adequate protective devices.
CAUTION! DO NOT TOUCH the FIRE DOOR, the GLASS, the HANDLE or the FUME OUTLET DURING OPERATION when not wearing adequate
protective clothing or devices as they become extremely hot!
Keep inflammable materials, such as furniture, cushions, pillows, blankets, paper, clothing, curtains, etc., at least 1.5 m away from the stove front and 30 cm
from the stove sides and back.
During operation, there is a risk of fire if the stove is covered or if it comes into contact with flammable material including curtains, draperies, covers, etc. KEEP
THE PRODUCT AWAY FROM SUCH MATERIALS.
Do not immerse the cable, plug or any other component of the appliance in water or other liquids.
Do not use the stove in dusty environments or wherever inflammable gases are generated (e.g. in a workshop or garage).
The stove is fitted with components that generate arcs and sparks. Do not install the stove in areas posing a significant fire or explosion hazard due to a high
chemical substance concentration or to a high humidity level.
Do not use the appliance close to bathtubs, showers, basins, sinks or swimming pools.
Do not install the appliance underneath an air vent. Do not install the stove outdoors.
Do not repair, disassemble or modify the appliance. The appliance is not fitted with components that can be repaired by users.
Turn off the stove, disconnect it from the mains and wait until it has cooled down completely before performing any maintenance operations.
WARNING: DISCONNECT THE STOVE FROM THE MAINS BEFORE PERFORMING ANY MAINTENANCE.
CAUTION! These stoves operate exclusively with pellets or olive pomaces if the stove is designed for this particular use; DO NOT USE DIFFERENT
COMBUSTIBLES: any other burned material will cause the apparatus to malfunction.
Keep the pellets in a fresh dry place: storing pellets in a place that is damp or excessively cold may reduce the stove potential heat output. Be
careful when storing and handling pellet bags to prevent pellet crushing and consequent sawdust production.
The fuel consists of small cylinders with 6-7mm diameter and a maximum length of 30mm. Their maximum moisture content is equal to 8%. This stove is
designed to burn pellets made of compacted sawdust obtained from different types of wood, in compliance with environment protection legislation.
The use of different types of pellets may result in a slight, sometimes even undetectable, change in the stove efficiency. This change can be counterbalanced
by increasing or decreasing the stove heat output by only one step.
Clean the burn pot on a regular basis upon every ignition or pellet refuelling.
The combustion chamber must be kept closed, except when loading or removing residues, in order to prevent smoke egress.
Do not switch the stove on and off intermittently to prevent damaging its electrical and electronic components.
Do not use the appliances as waste incinerators or for any other purpose other than that for which they were designed.
Do not use liquid fuels.
Do not modify the appliance without prior authorisation.
Use only original spare parts recommended by the manufacturer.
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Eva Calor Sola at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Eva Calor Sola in the language / languages: English as an attachment in your email.

The manual is 4.77 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Eva Calor Sola

Eva Calor Sola User Manual - German - 43 pages

Eva Calor Sola User Manual - Dutch - 43 pages

Eva Calor Sola User Manual - French - 43 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info