The calorific value depends therefore, on the density of the wood (that varies based on its type) and on its moisture content. The heat output of the stoves is directly
affected by this factors. Depending on its moisture content, it can be indicated in:
% of humidity
Calorific heat output kcal/kg
15%
3490
20%
3250
25%
3010
30%
2780
35%
2450
40%
2300
On average, a well seasoned wood has a calorific value of 3200 kcal/kg.
06. INSTALLATION WARNINGS
06.1 HERMETIC STOVE
The hermetic wood stove body is available for outputs 8 and 12.5 kW. If properly connected by means of a suction tube, these stoves draw the combustion air and
the air necessary for glass cleaning directly from outside and not from the room where they are installed, preserving the oxygen in the room. Using coaxial tubes,
the air will be pre-warmed contributing to improved combustion and lower emissions into the atmosphere. Ideal for passive houses, they offer best comfort at the
lowest cost.
Before installation, the following indications must be respected:
Select the position where the stove is to be installed and:
•Choose whether the appliance will have a rear or upper flue gas outlet.
•Provide the connection to the flue pipe for the expulsion of the fumes.
•Provide the external airintake (combustion air) and check for its presence: it must be drawn from a free space (not spaces where extractor fans existor
without ventilation) or from outside.
•Place the stove on the floor in a position that is advantageous for connection with the flue pipe and near the "combustion air" intake
•The appliance must be installed on a floor with an adequate loading-bearing capacity. Should the existing floor not comply with the requirement above, proper
measurements must be taken (for instance, the installation of a load distribution plate).
•All the structures which could catch fire if exposed to excessive heat must be protected. Flooring made from wood or inflammable materials must be protected
using non-combustible materials (e.g. 4mm-thick sheet metal or ceramic glass).
•The appliance installation must ensure easy access for cleaning of the stove, exhaust pipes and flue pipe.
•This appliance is not suitable to be installed on a shared flue pipe.
•During normal operation, the stove draws air from the room where it is installed. Therefore, an external air intake must be positioned at the same height of the
pipe located on the stove back. When it is operational, the stove can cause a negative pressure in the room where it is installed. Therefore there should not
be other naked flame devices in the same room.
•The combustion air intake (Ø 80mm) must be connected directly to the outside or to adjacent rooms provided
they are fitted with external air supply vents (Ø 80mm) and are not used as bedrooms or bathroomsor, whenever
a fire hazard exists, as storage rooms, garages, combustible material warehouses, etc. The air vents must be
placed in such a way that they cannot be clogged either from the outside or inside and must be protected using
a grille, a metal mesh or other suitable means provided they do not reduce the minimum section. For the
connection to the external intake, it is necessary to break the pre-cuts in the lower part of the stove back and to
connect the pipes with a dedicated seal to the appropriate intake.
•If the stove is to be installed in rooms where it is surrounded by combustible materials (e.g. furniture, wood
cladding, etc.), the following minimum clearances must be complied with: "SEE STOVE DATA PLATE”
•The 8.5 kW stove does not have a connection to the combustion air intake.
•It is however advisable, in addition to respecting the minimum distances, to install heat-resistant flame-retardant
Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.
Product:
Forumrules
To achieve meaningful questions, we apply the following rules:
First, read the manual;
Check if your question has been asked previously;
Try to ask your question as clearly as possible;
Did you already try to solve the problem? Please mention this;
Is your problem solved by a visitor then let him/her know in this forum;
To give a response to a question or answer, do not use this form but click on the button 'reply to this question';
Your question will be posted here and emailed to our subscribers. Therefore, avoid filling in personal details.
Register
Register getting emails for Eva Calor Patty at:
new questions and answers
new manuals
You will receive an email to register for one or both of the options.
Get your user manual by e-mail
Enter your email address to receive the manual of Eva Calor Patty in the language / languages: English as an attachment in your email.
The manual is 2.3 mb in size.
You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.
If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.
The email address you have provided is not correct.
Please check the email address and correct it.
Your question is posted on this page
Would you like to receive an email when new answers and questions are posted? Please enter your email address.