The thermostat switches off the Auger tube, being connected in series to its power supply, the control board reports the alarm status (alarm LED on) by showing
the message “AL7 SAFETY THERMAL” on the display and the stove switches off.
AL8 FAILURE DEPRESS - No negative pressure alarm
The alarm is triggered whenever the external pressure switch detects a pressure higher value below the trigger threshold. The pressure switch switches off the
Auger tube, being connected in series to each other, and the control board reports the alarm status (alarm LED on) by showing the message “AL8 FAILURE
DEPRESS” on the display. The stove switches off.
05.5 ELECTRONICS WITH REMOTE CONTROL p. 4 F-5
(Pellet stoves)
PROPER FUNCTIONING AND CONTROL ADJUSTMENT DEVICES
Control panel
The control panel shows the information concerning the stove status. Several types of data can be displayed and the settings available according to the access level
can be modified by entering the menu.
Depending on the selected mode and on their position on the display, the data visualized may acquire different meanings.
PANEL DESCRIPTION
DISPLAY (P0)
BUTTON (P1) - Decrease:
When in programming mode, use this button to modify/decrease the selected menu value. When in WORK/OFF, use instead this button to decrease the room
thermostat temperature value or stove heat output.
BUTTON (P2) - Increase:
When in programming mode, use this button to modify/increase the selected menu value. When in WORK/OFF, use instead this button to increase the room
thermostat temperature value or the stove heat output.
BUTTON (P3) - ON/OFF Unlocking:
Hold this button down for two seconds to manually switch the stove on or off respectively depending on its initial status OFF or START.
Press it once to go back to the previous menu and up to the initial screen.
Should have any alarm blocked the stove, press this button to unlock the stove and subsequently switch it OFF.
BUTTON (P4) – Set Room Temperature value:
When in WORK mode, use this button to access the set room temperature value. In menu mode, use this button to go back to the previous menu item or, in
programming mode, to go back to the previous sub-menu item. Any change is automatically saved.
BUTTON (P5) – Set Heat Output value:
When in WORK mode, use this button to access the heat output value. In menu mode, use this button to move to the next menu item, while, in programming
mode, to move to the subsequent sub-menu item. Any change is automatically saved.
BUTTON (P6) – Return:
Serves to return to the previous menu.
BUTTON (P7) - Set/menu:
Use this button to access user and technician parameter menu. After entering the menu, use this button to access the next sub-menu level or set the value and
move to the next menu item when in programming mode.
BUTTON (T1) ON/OFF button: to manually switch the stove on or off
BUTTON (T2) + button: heat output increase
BUTTON (T3) - button: heat output decrease
LED (L1) Signal LED: it confirms that signal has been received
LED (L2) Alarm LED: it indicates the stove alarm status. Clear using on/off button
MENU
Press P7 (MENU) button to access the menu.
It includes several items and levels to access settings and control board programming. The menu items providing access to the technical setting are protected
by access code.
Menu M2 – SET CLOCK
Use this function to set current time and date. The control board is equipped with a lithium battery guaranteeing the internal time clock a 3/5 year-long life.
Menu M3 – SET CHRONO
Submenu M3 -1 ENABLE CHRONO
The programmable thermostat functions can be disabled and enabled.
Submenu M3 - 2 PROGRAM DAY
The daily programmable thermostat functions can be enabled, disabled and set
It is possible to set two on/off times defined by the times set according to the table below. If the value is set to OFF, the time clock ignores the control:
settingmeaningavailable values
START 1 switchin on time time - OFF
STOP 1 switching off time time - OFF
START 2 switchin on time time - OFF
STOP 2 switching off time time - OFF
Submenu M3 - 3 PROGRAM WEEK
The weekly programmable thermostat functions can be enabled, disabled and set.
The weekly programmer consists of 4 independent programmes which can be combined together in different ways.
The weekly programmer can be enabled or disabled.
Moreover, if the time is set to OFF, the time clock ingnores the corresponding control.
N.B.: set the programming carefully in order to avoid overlapping of switching on and/or off times of different programmes on the same day.
Submenu M3 - 4 PROGRAM WEEK-END
The programmable thermostat functions can be enabled, disabled and set for the week-end (days 6 and 7, or Saturday and Sunday).
TIP: if you still do not know exactly the result you want to obtain, enable only one programme at a time to avoid confusion and unwanted stove switching on and off.
Disable the daily programme if you want to use the weekly programme. If you use the weekly programme for 1, 2, 3 and 4 programmes, never enable the week-end
programme.
Always disable the weekly programme before enabling the week-end programme.
Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.
Product:
Forumrules
To achieve meaningful questions, we apply the following rules:
First, read the manual;
Check if your question has been asked previously;
Try to ask your question as clearly as possible;
Did you already try to solve the problem? Please mention this;
Is your problem solved by a visitor then let him/her know in this forum;
To give a response to a question or answer, do not use this form but click on the button 'reply to this question';
Your question will be posted here and emailed to our subscribers. Therefore, avoid filling in personal details.
Register
Register getting emails for Eva Calor Paola at:
new questions and answers
new manuals
You will receive an email to register for one or both of the options.
Get your user manual by e-mail
Enter your email address to receive the manual of Eva Calor Paola in the language / languages: English as an attachment in your email.
The manual is 5,83 mb in size.
You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.
If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.
The email address you have provided is not correct.
Please check the email address and correct it.
Your question is posted on this page
Would you like to receive an email when new answers and questions are posted? Please enter your email address.