814234
10
Zoom out
Zoom in
Previous page
1/16
Next page
08. USER FUNCTIONS
Stove ignition
To light the stove, small (dry) logs and possibly ecological fire-lighters are required. Open the primary and secondary air adjustment device using the levers and
position the logs as in the photo. After positioning the logs, place the fire starters below the wood and light them up. Close the door and wait for the flame to ignite
all the wood logs positioned, then close the primary air adjustment device. Failure to close this adjustment device could cause the stove to overheat and its parts
to break.
Good ignition depends very much on the draught of the flue pipe: if the ignition is difficult, the flue pipe will not have the recommended draught due to the fact that
it is cold and the stove will require more time to reach the intended operating conditions.
In this case, we recommend that you open the ash drawer or keep the fire door slightly open.
ATTENTION: never use flammable liquids to light the logs.
Furthermore, the paint could still be fresh and could release intense odours: regarding the first ignition, the environment should be well ventilated. Open doors
and windows in order to obtain an air current that frees the room from odours.
It is also possible that the product may undergo slight deformations, as the structure is made of steel, and therefore slight noises or crunches may be heard. This
is absolutely normal and should not be considered a defect.
Combustion
To obtain the best combustion, follow the parameters below:
8 kW stoves
8.5 kW stoves
12.5 kW stoves
Amount of wood (kg/h)
1.9
2
2.9
Primary air register
Closed
½ open
Closed
Secondary air adjustment device
Almost fully open (80%)
/
Open
Refuelling interval (min)
45
45
45
Wood log length (cm)
25
25
33
Draught (Pa)
12
10
12
Once the stove is started up and is fully operational, it will be possible to regulate combustion through the secondary air adjustment device located in the upper
part of the stove. The right knob functions in the same way as the lever. By turning the knob clockwise, the air grille will be closed; conversely, by turning the knob
anti-clockwise the air grille will be opened
As for the 8.5 kW stove, combustion cannot be regulated with the secondary air adjustment device because it is not present. The only way to regulate it is to act
on the primary air regulator located on the firebox door.
10
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Eva Calor Marica at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Eva Calor Marica in the language / languages: English as an attachment in your email.

The manual is 2.3 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Eva Calor Marica

Eva Calor Marica User Manual - German - 16 pages

Eva Calor Marica User Manual - French - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info