814129
10
Zoom out
Zoom in
Previous page
1/17
Next page
07. CLEANING AND ROUTINE MAINTENANCE
The stove requires simple and frequent cleaning to guarantee maximum efficiency and correct operation.
The Buyer must carry out regular cleaning of the stove following the instructions contained in this Instruction Manual, and in particular must carry out daily cleaning
before each ignition or refilling of pellets, the ash drawer, the fire pit and the combustion chamber.
Failure to clean and/or routinely maintain the stove can cause: malfunctions, clogging of the burn pot
and pipes, poor or slow combustion, overheating of the stove and fire in the tank.
Eva Stampaggi S.r.l. assumes no criminal and/or civil liability, direct and/or indirect for the
malfunction of the stove and for damage to persons or property caused by the failure/incorrect
cleaning and routine maintenance of the stove.
Perform daily cleaning in a completely cold stove as follows:
Vacuum the base of the fire pit inside the combustion chamber
Perform weekly cleaning in a completely cold stove as follows:
Vacuum the combustion chamber, ensuring that there are no burning embers remaining.
If embers are still burning, the vacuum cleaner will catch fire;
Remove the ash that collects inside the fire box and on the door.
Clean the glass with a damp cloth or with a ball of damp newspaper dipped in ash. If the
operation is performed with the stove hot there is a risk of the glass exploding.
Empty the ash drawer, by vacuuming it or throwing the ash out with the rubbish.
Vacuum the ash drawer compartment and the adjacent inspection window.
Perform monthly cleaning in a completely cold stove as follows:
Vacuum the T lid of the fume connection. Open the side inspection window and remove the T lid.
Caution: Only use a dry cloth to clean the stove. Do not use abrasive material or products that could corrode or bleach surfaces. At the end of the season, with the
last ignition, the pellet remaining in the auger must be consumed completely. The auger must remain empty to avoid clogging due to solidified sawdust residue
created by moisture.
PELLET COOKER ONLY
It is also possible to raise the plate (or glass) and vacuum the fume circulator.
When the fume circulator is clean ensure the plate is well positioned.
08. EXTRAORDINARY MAINTENANCE
The Buyer must have the flue and flue pipe cleaned annually, before winter, by qualified technical personnel and retaining the documentation to be shown in the
event of activation of the warranty.
Before performing maintenance it is recommended to turn the stove off using the power button, and remove the plug.
Cleaning must also be carried out before resuming use of the stove, as during the summer there may have been impediments to the regular flow of exhaust gases
(e.g. nesting, fouling or obstruction).
The lack of extraordinary maintenance can cause: depression with poor draught and a slow flame, clogging of the burn pot and pipes, overheating of the stove and
fire in the smoke pipe.
Eva Stampaggi S.r.l. assumes no criminal and/or civil liability, direct and/or indirect for the malfunction and those resulting from people or things caused by the
failure/incorrect extraordinary maintenance of the stove.
It is not uncommon, at the first cold spell and with wind for fires to ignite in the chimney due to the residue build up; some advice in the unfortunate event of this
happening is:
Block air supply to the pipe immediately;
Use large handfuls of sand or salt, not water, to extinguish the fire;
Move objects and furniture away from the hot chimney.
Caution: Only use a dry cloth for cleaning the outside of the stove. At the end of the season, with the last ignition, the pellet remaining in the auger must be
consumed completely. The auger must remain empty to avoid clogging due to solidified sawdust residue created by moisture.
9
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Eva Calor Kali at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Eva Calor Kali in the language / languages: English as an attachment in your email.

The manual is 2.19 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Eva Calor Kali

Eva Calor Kali User Manual - German - 16 pages

Eva Calor Kali User Manual - Dutch - 38 pages

Eva Calor Kali User Manual - French - 17 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info