By using coaxial tubes, the air will be pre-warmed contributing to improved combustion and
lower emissions into the atmosphere.
Before installing, the following indications must be met:
Select the position where the stove is to be installed and:
•Arrange the connection to the vent pipe for fume extraction.
•Arrange the external air intake (combustion air).
•Arrange the connection to the earthed mains.
•The electrical system of the room where the stove is to be installed must be earthed,
otherwise the control board may not work properly.
•Place the stove on the floor in a convenient position for the connection to the vent pipe and
close to the combustion air intake.
•The appliance must be installed on a floor with an adequate loading-bearing capacity.
•Should the existing floor not comply with the requirement above, proper measurements
must be taken (for instance, the installation of a load distribution plate).
•All the structures which couldcatch fire if exposed to excessive heat must be protected. Floors made from wood or inflammable materials must be protected
using non-combustible materials (e.g. 4mm-thick sheet metal or ceramic glass).
•The appliance installation must ensure easy access for cleaning the stove, exhaust pipes and vent pipe.
•This appliance is not suitable to be installed on a shared vent pipe.
•During normal operation, the stove draws air from the room where it is installed. Therefore, an external air intake must be positionedat the same height of the
pipe located on the stove back. Exhaust fume pipes must be suitable for pellet stoves and must therefore be made from coated steel or stainless steel, with a
diameter of 8cm and fitted with adequate gaskets.
•The "air combustion" socket must reach an external wall or a wall of an adjacent room with external ventilation, as long it is not a bedroom or bathroom, nor
at risk of fire such as garages, storage rooms, combustibles stores, etc. These air vents must be made in such a way that they cannot be blocked either
internally or externally and should be protected by a grille, e metal net or other suitable protection without reducing the minimum dimensions.
AIRTIGHT STOVE ONLY
Airtight stoves take combustion and glass cleaning air directly from outside, not from the room where they are situated, if correctly attached
by a suction tube. In this way, no oxygen is consumed from the immediate environment. Using coaxial tubes the airwill be pre-warmed
contributing to improved combustion and lower emissions into the atmosphere. Ideal for passive houses, they offer best comfort at the
lowest cost. The stove works even if not connected to the external air intake.
It is in any case advisable, as well as respecting minimum distances, to install the fireproof heat-resistant insulating panels (mineral wool, aerated concrete, etc.)
The following is recommend:
Promasil 1000
Classification temperature: 1000 °C
Density: 245 kg/m3
Shrinkage at reference temperature, 12 h: 1.3/1000°C %
Cold crushing strength: 1.4 MPa
Bending strength: 0.5 MPa
Reversible thermal expansion: 5.4x10-6 m/mK
•When the stove is on, it can create a depression in the room where it is installed, therefore there must not be any open flame apparatus in the same room,
with the exception of type C boilers (airtight).
•Make sure that the stove can draw the necessary quantity of combustion air: this must be from an open space (i.e. a space without exhaust blowers or
providing adequate ventilation) or directly from outside.
•Do not install the stove in bedroomsor bathrooms.
•Unpack the stove: be careful not to damage the product at the time of unpacking.
•Check the stove's legs and adjust them so that the stove is stable.
•Place the stove so that the door and any window openings are not against the walls.
•After connecting the stove to the combustion air inlet join the coupling device to the vent pipe.
Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.
Product:
Forumrules
To achieve meaningful questions, we apply the following rules:
First, read the manual;
Check if your question has been asked previously;
Try to ask your question as clearly as possible;
Did you already try to solve the problem? Please mention this;
Is your problem solved by a visitor then let him/her know in this forum;
To give a response to a question or answer, do not use this form but click on the button 'reply to this question';
Your question will be posted here and emailed to our subscribers. Therefore, avoid filling in personal details.
Register
Register getting emails for Eva Calor Ines at:
new questions and answers
new manuals
You will receive an email to register for one or both of the options.
Get your user manual by e-mail
Enter your email address to receive the manual of Eva Calor Ines in the language / languages: English as an attachment in your email.
The manual is 2.19 mb in size.
You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.
If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.
The email address you have provided is not correct.
Please check the email address and correct it.
Your question is posted on this page
Would you like to receive an email when new answers and questions are posted? Please enter your email address.