18. HYDRO STOVE ANOMALIES AND POSSIBLE SOLUTIONS
PROBLEM CAUSE SOLUTION
FIRST START-UP IT MAY BE NECESSARY TO REPEAT THE FIRST LOAD PHASE A FEW TIMES TO FACILITATE THE APPLIANCE INITIAL START-
UP AS THE
AUGER TUBE IS COMPLETELY EMPTY AND IT MAY TAKE A SPECIFIC PERIOD OF TIME TO FILL.
DISPLAY
SWITCHED OFF
POWER OUTAGE CHECK PLUG AND POWER SUPPLY.
FAULTY ELECTRICAL CABLE CALL TECHNICAL SUPPORT.
INTERRUPTED FUSE IN
CONTROL BOARD
CALL TECHNICAL SUPPORT.
FAULTY CONTROL BOARD CALL TECHNICAL SUPPORT.
FAULTY DISPLAY CALL TECHNICAL SUPPORT.
ALARM NO FIRE
PELLETS
NOT FED TO
BURN POT
PELLETS
FALL BUT
NOT LIT
STOVE
SWITCHES
OFF DURING
NORMAL
FUNCTIONIN
G
NO PELLETS CHECK HOPPER.
SAFETY THERMOSTAT
TRIGGERED
MANUALLY RESET THE THERMOSTAT LOCATED ON STOVE BACK
AUGER TUBE BLOCKED BY
FOREIGN BODY
DISCONNECT PLUG, EMPTY HOPPER, REMOVE ANY FOREIGN BODY, SUCH AS NAILS, ETC.
FAULTY AUGER TUBE MOTOR CALL TECHNICAL SUPPORT.
ACTIVE ALARM SEE ALARM SECTION.
DIRTY BURN POT CLEAN BURN POT.
TEMPERATURE TOO COLD REPEAT SWITCHING-ON PHASE SEVERAL TIMES, EMPTYING THE BURN POT UPON EACH
TIME.
DAMP PELLETS CHECK PELLET STORAGE LOCATION.
FAULTY GLOW PLUG CALL TECHNICAL SUPPORT.
FAULTY FUME SENSOR CALL TECHNICAL SUPPORT.
FAULTY EXHAUST BLOWER CALL TECHNICAL SUPPORT.
FAULTY CONTROL BOARD CALL TECHNICAL SUPPORT.
POWER OUTAGE CHECK PLUG AND POWER SUPPLY.
NO PELLETS CHECK HOPPER.
AUGER TUBE BLOCKED BY
FOREIGN BODY
DISCONNECT PLUG, EMPTY HOPPER, REMOVE ANY FOREIGN BODY, SUCH AS NAILS, ETC.
POOR-QUALITY PELLETS CHANGE PELLET TYPE.
INSUFFICIENT PELLET SET
VALUE AT MINIMUM HEAT
OUTPUT
CALL TECHNICAL SUPPORT.
ACTIVE ALARM SEE ALARM SECTION.
POOR FLAME
ANTI-EXPLOSION DEVICE PLUG MISSING OR NOT CORRECTLY POSITIONED.
PARTIALLY CLOGGED FLUE
PIPE
CLEAN FLUE PIPE IMMEDIATELY.
COMBUSTION AIR NOT
SUFFICIENT
CLOGGED AIR INTAKE.
CLOGGED STOVE CLEAN BURN POT AND ASH DRAWER.
FAULTY/DIRTY EXHAUST
BLOWER
GET IT CLEANED BY A SPECIALISED TECHNICIAN CALL TECHNICAL SUPPORT.
INADEQUATE COMBUSTION AIR
SET VALUE
CALL TECHNICAL SUPPORT.
ALARM NO
NETWORK
POWER OUTAGE SWITCH STOVE ON AND OFF, CHECK PLUG.
RiS/ECO SET ROOM TEMPERATURE REACHED/CORRECT OPERATION.
DISPLAY DOES
NOT WORK
SET ROOM TEMPERATURE
REACHED
INCREASE SET ROOM TEMPERATURE SO THAT APPLIANCE GOES BACK TO "WORKING"
MODE.
STOP FIRE PERIODIC CYCLE OF BURN POT
CLEANING
CORRECT OPERATION.
ALARM DEP
EXCESSIVE OR INADEQUATE
FLUE PIPE LENGTH
NON-COMPLIANT VENT PIPE.
CLOGGED OUTLET CLEAN FLUE PIPE/CALL AUTHORISED TECHNICIAN.
BAD WEATHER CONDITIONS STRONG WIND.
36


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Eva Calor Hydro17.5 KW at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Eva Calor Hydro17.5 KW in the language / languages: English as an attachment in your email.

The manual is 4.77 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Eva Calor Hydro17.5 KW

Eva Calor Hydro17.5 KW User Manual - German - 43 pages

Eva Calor Hydro17.5 KW User Manual - Dutch - 43 pages

Eva Calor Hydro17.5 KW User Manual - French - 43 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info