668835
43
Zoom out
Zoom in
Previous page
1/55
Next page
What to do
Put the stove in stand-by by pressing the off button for a few seconds (4).
Try switching the stove back on.
Contact your service centre if the problem persists.
AL 5 – No start
This alarm signals an ignition failure. This alarm is activated when, during the start-up
phase, a maximum waiting time (about 20 minutes) is exceeded without the machine
switching on successfully. (see ignition)
AL 6 – No pellet
This alarm indicates a flame failure in the brazier during normal stove operation. The main
causes are: no pellets in the hopper or blocking of the pellet feed screw.
What to do
Put the stove in stand-by by pressing the off button for a few seconds (4).
Empty the brazier of all unburned accumulated pellets.
In the event of pellet exhaustion in the tank, refuel the stove and ignite it again. Do not insert
pellets until the stove has cooled completely. Pellet refilling must be performed with the
stove off or with the stove working with the flame present.
In the case of a pellet feed screw block, empty the tank and remove any foreign bodies
present in the feed screw. Then refill with pellets and start the stove back up.
In the case of repeated feed screw blocks, call a service centre.
AL 7 – Thermal safety
This alarm is activated by intervention of the stove boiler safety thermostat (see safety
devices).
AL 8 – Low pressure
This alarm is activated by intervention of the pressure sensor (pressure gauge) (see safety
devices).
AL 9 – Water sensor
This alarm is activated by the breaking or disconnection of the water sensor from the boiler
(see safety devices).
AL A – Water temp
This alarm is activated by the overtemperature of the water in the boiler (see safety devices).
AL b – Water press
This alarm is activated by the incorrect pressure of the water in the boiler (see safety
devices).
43


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Eva Calor Hydro Slim Kantina 16 kW at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Eva Calor Hydro Slim Kantina 16 kW in the language / languages: English as an attachment in your email.

The manual is 5,06 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info