668834
30
Zoom out
Zoom in
Previous page
1/55
Next page
Ventilation speed is proportional to operating power and cannot be modified independently with
respect to stove power.
In channelled air models, the stove has two rear hot air outputs, one on the right and the other on
the left, under the pellet tank. Each of the two outputs has an independent control menu (see
chapter 7 menu).
6.3.7 Circulator (hydro and boiler models)
Hydro models have a circulator and an expansion tank for direct connection of the system stove
to radiators. The circulator starts as soon as water reaches a temperature of 55° C (value that must
not be lowered to prevent formation of condensation in the stove) and works according to water
temperature, even with the stove off. A bleed screw is available on the back of the stove to remove
any air in the circulator itself.
6.3.8 External thermostat
Stove operation can be adjusted to any external room thermostat connected to the circuit board
(see electrical diagram). The thermostat connection is made using a 2x0.5 mm2 cable. This
operation should be performed by qualified personnel.
The external thermostat works in parallel to the internal thermostat of the stove. To work the
external thermostat exclusively, set room temperature to minimum (7° C). At this point, stove
modulation will be controlled by the external thermostat.
During the working phase, if the room temperature is lower than the set temperature and the
external thermostat is active (closed contact), the stove will operate at the set power level. When
the room temperature reaches the set temperature, (external thermostat contact open), the stove
will go to minimum power and the display will show the message "MODULATE". This modulation
has been completed only if the room temperature returns to being lower than the set temperature
in the external thermostat.
Ambient
sensor
Thermostat
6.3.9 Brazier cleaning
During normal operation in work mode, "BRAZIER CLEANING" is activated at set intervals for a
duration of about 45 seconds. During this time, the display will show the message "BRAZIER
CLEANING", stove ventilation increases and the flame lowers in the brazier. This operation is
necessary to decrease the likelihood of ash accumulation of ash inside the brazier.
If you notice an excessive accumulation of pellets in the brazier (over half the level of the
brazier itself), immediately switch off the stove and clean the brazier. Promptly contact a
service centre.
6.3.10 Shutdown
To turn off the stove, hold button 4 for a few seconds .
Once the shutdown signal has been received, the display will show a "FINAL CLEANING"
message and the fume exhaust fan will continues to run at full speed for a minimum time of about
10 minutes to ensure complete cooling of the stove. The hot air fan will also continue to run until
the stove cools down.
CAUTION: Never disconnect the power supply at this stage, as this may create problems
for the stove and compromise the subsequent phases of ignition.
30


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Eva Calor Hydro Slim 16 kW at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Eva Calor Hydro Slim 16 kW in the language / languages: English as an attachment in your email.

The manual is 5,06 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info