4.3 Flooring protection
In the event of valuable flooring or flooring that is sensitive to heat, moisture or is flammable, a floor protection
must be used (i.e. sheet steel, marble or tile slabs).
Whichever type of protection selected, it must protrude at least 300 mm from the front, at least 150 mm from
the sides of the stove, must withstand the weight of the stove and have a thickness of at least 2 mm (Fig. 6
and 7).
Fig. 6 Fig. 7
4.4 Minimum distances for positioning air intake vents
Pellet stove combustion air intake vents cannot be connected to an air distribution system
or directly to a wall-mounted air intake vent.
Correct and safe positioning of the air intake vent must comply with the measures and requirements
described in paragraph 1.3.
There are distances to be respected in order to avoid that combustion air be removed by another
source; for example, a window opening can suck the air outside, making it miss the stove.
The air intake vent must be located at
least:
1.5 m
under
Doors, windows, fume
exhaust outlets, air
gaps, etc.
1.5 m
Horizontally away
0.3 m
Over
1.5 m
Away from
Fume output
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Eva Calor Hydro 27 kW at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Eva Calor Hydro 27 kW in the language / languages: English as an attachment in your email.

The manual is 5,06 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Eva Calor Hydro 27 kW

Eva Calor Hydro 27 kW User Manual - German - 38 pages

Eva Calor Hydro 27 kW User Manual - Dutch - 90 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info