668826
36
Zoom out
Zoom in
Previous page
1/47
Next page
04. PRODUCT USE
35
Stove switched off
The display will show the wording OFF. The fume fan stops working.
Stove re-ignition
It will be possible to switch the stove back on only at the end of the safety period of time set by Pr38 and if the fume temperature has
reached a value below Pr13.
What happens in case of...
Pellet ignition failure
If the pellets do not ignite, the display shows the alarm message “NO ACC” as shown in figure 25.
fig. 25
black-out
Pr48 = 0
When the power is resumed after an outage, the stove enters the FINAL CLEANING phase and waits until the fume temperature
reaches a value below Pr13.
fig. 26
Pr48 = T seconds
After a power outage, one of the following conditions may occur depending on the stove previous status:
previous status
black-out duration
new status
switched off
any
switched off
ignition
< T
ignition
pellet loading without pre-load
< T
pellet loading
pellet loading with pre-load
any
switching off
waiting for flame
< T
waiting for flame
working mode
< T
working mode
burn pot cleaning
< T
burn pot cleaning
switching off
< T
switching off
If the power outage duration is longer than T, the stove switches off.
36


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Eva Calor Hydro 20 kW at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Eva Calor Hydro 20 kW in the language / languages: English as an attachment in your email.

The manual is 4,1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Eva Calor Hydro 20 kW

Eva Calor Hydro 20 kW User Manual - German - 38 pages

Eva Calor Hydro 20 kW User Manual - Dutch - 90 pages

Eva Calor Hydro 20 kW User Manual - French - 43 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info