04. PRODUCT USE
Menu 04 - stand-by-mode - activate mode 2
If you select the “STAND-BY” mode, the stove switches off after a period of time, set by Pr44, during which the room temperature
remains at a value higher than the SET temperature.
Only if the following condition occurs it is then possible to switch the stove back on: TSET < (Tstove-Pr43)
FOR THE INSTALLER:
There are 3 standby modes:
Mode 1
WITH RESPECT TO THE AMBIENT SENSOR AND THE TEMPERATURE OF THE WATER
Having set the water temperature, commence operation of the stove.
1 - With the environment set reached the stove goes into stand by.
2 - With the air set not reached the stove is operational
Nearing Set Water, the stove goes into modulation and remains in modulation.
Only go into stand by when air Set has been reached.
It comes on again with a value below air Set.
The AMBIENT SENSOR takes priority
Mode 2:
WITH RESPECT ONLY TO THE WATER TEMPERATURE
Having set the water temperature, commence operation of the stove.
Nearing the Water Set, the stove goes into modulation and when the Set is exceeded, modulation and then stand by are enabled.
Below Set the stove comes on again and resumes operation.
The stove in no way considers the temperature measured by the ambient sensor of the same stove.
The WATER TAKES PRIORITY
Mode 3:
WITH RESPECT TO THE THERMOSTAT AND TO THE TEMPERATURE OF THE WATER
Having set the water temperature, commence operation of the stove.
1 - With thermostat open the stove goes into modulation and then stand by
2 - With thermostat closed the stove is operational
Nearing Set Water, the stove goes into modulation and remains in modulation. It only goes into stand by mode when the
thermostat opens the contact. It turns on when the thermostat closes the contact.
The stove in no way considers the temperature measured by the ambient sensor of the same stove.
The THERMOSTAT TAKES PRIORITY
Menu 05 - buzzer mode
Set it to “OFF” to disable the buzzer.
Menu 06 initial load
This function is important if the stove is new or if the stove is off due to the absence of pellets in the hopper.
INITIAL IGNITION MUST BE PERFORMED BY AUTHORISED PERSONNEL ONLY NOT BY THE PURCHASER.
CONTACT THE SERVICE CENTER THAT WILL SEND OUT A SPECIALIST TECHNICIAN TO YOU.
Use this function to pre-load pellets for a period of 90 seconds when the stove is switched off
and cold. Press P1
button to start and P4 button to stop.
32


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Eva Calor Hydro 20 kW at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Eva Calor Hydro 20 kW in the language / languages: English as an attachment in your email.

The manual is 4,1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Eva Calor Hydro 20 kW

Eva Calor Hydro 20 kW User Manual - German - 38 pages

Eva Calor Hydro 20 kW User Manual - Dutch - 90 pages

Eva Calor Hydro 20 kW User Manual - French - 43 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info