668826
24
Zoom out
Zoom in
Previous page
1/47
Next page
03. INSTALLING THE PRODUCT
23
INSTALLATION
In compliance with the current regulations for installation, the pellet thermo-stove should be installed in a ventilated place with air
that is sufficient to ensure correct combustion and therefore good operation. The room must have a volumetry of no less than 20 m3
and to ensure good combustion (40 m3/h of air), there must be a combustion air intake" that must reach a wall that connects to the
outside or to adjacent rooms provided they are fitted with external air supply vents (Ø80mm) and are not used as bedrooms or
bathrooms or, whenever a fire hazard exists, as storage rooms, garages, combustible material warehouses, etc. These air vents must
be placed in such a way that they cannot be clogged either from the outside or inside and must be protected using a grille, a metal
mesh or other suitable means provided they do not reduce the minimum section.
When it is operational, the thermo-stove can cause a negative pressure in the room where it is installed. Therefore there should not
be in the same room other naked flame devices, with the exception only of type c stoves (watertight) unless they are fitted with their
own air flow.
They must not be positioned close to curtains, armchairs, furniture or to other flammable materials.
They must not be installed in explosive or potentially explosive environments which may become explosive due to the presence of
machinery, materials or dust that can cause greenhouse gas emissions or which can easily ignite with sparks. Before attempting to
install the pellet thermo-stove, bear in mind that all fixtures or any beams made of combustible material must be placed at a safe
distance and outside the radiation area of the stove itself. Also consider that in order not to compromise the correct operation of
the appliance, it is essential to create air circulation inside its casing. This helps prevent overheating and can be achieved by respecting
the minimum distances and by creating a number of ventilation holes.
Internally, the thermo-stove is equipped with all the components for safety: automatic ventilating valve, 3-bar safety valve, expansion
tank and stove safety thermostat. Remember to discharge the hydraulic system before switching on the appliance.
The use of hosing is recommended that connects the appliance to the hydraulic system as, in the case of ordinary or extraordinary
maintenance, this makes it easy to move. It is also recommended to install a dirt separator as the electronic pump could capture the
dirt of the system and become jammed.
ELECTRICAL CONNECTION
The electrical connection must be performed by qualified personnel who install circuit breakers upstream of the appliance.
Extra attention we need to do when the stove are an integration to the plant and all the machines have to work like the program.
Avoid installations with electric cables that run close to fume pipes or hot components that are suitably insulated.
The voltage is 230 V while the frequency is 50 Hz.
The electrical system where it is connected must be fitted with a conductor as required by the Regulations 73/23 EEC and 93/98 EEC.
EXTERNAL THERMOSTAT
In these thermo-stoves it is possible to install an external thermostat. This operation may only be performed by authorised personnel.
Use a 2-pole cable with everyday double insulation. In the event that the thermostat is closed, the stove functions at the power set.
If the thermostat opened, the stove would work in MODULATE mode until the thermostat closes.
First connect the stove plug to the mains and load the pellet hopper.
Be careful not to empty the entire bag at once. Perform this operation slowly.
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Eva Calor Hydro 20 kW at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Eva Calor Hydro 20 kW in the language / languages: English as an attachment in your email.

The manual is 4,1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Eva Calor Hydro 20 kW

Eva Calor Hydro 20 kW User Manual - German - 38 pages

Eva Calor Hydro 20 kW User Manual - Dutch - 90 pages

Eva Calor Hydro 20 kW User Manual - French - 43 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info