03. INSTALLING THE PRODUCT
15
03.3 CHIMNEY COWL
A properly installed chimney cowl ensures optimum stove functioning. The anti-downdraught chimney cowl consists of a number
of components whose outlet section sum always doubles the vent pipe section. Make sure the chimney cowl is at least 150cm
above the roof top so that it is fully exposed to the wind.
The chimney cowls must:
have useful outlet section that is at least twice that of the vent pipe.
be made in such a way as to prevent the penetration of rain or snow.
be constructed in such a way as to ensure, in the event of winds coming from any direction, the evacuation of combustion
products.
be free of mechanical intake auxiliaries.
Roof pitch α [°]
Horizontal width of reflux zone
measured from top A axis [m]
Minimum height from roof for
discharging exhaust fumes H min
=Z+0.50m
Height of reflux zone Z [m]
15
1.85
1.00
0.50
30
1.50
1.30
0.80
45
1.30
2.00
1.50
60
1.20
2.60
2.10
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Eva Calor Hydro 20 kW at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Eva Calor Hydro 20 kW in the language / languages: English as an attachment in your email.

The manual is 4,1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Eva Calor Hydro 20 kW

Eva Calor Hydro 20 kW User Manual - German - 38 pages

Eva Calor Hydro 20 kW User Manual - Dutch - 90 pages

Eva Calor Hydro 20 kW User Manual - French - 43 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info