Changing set stove temperature
To change the room temperature, simply press the P1 button. The display shows the current SET temperature value.
External thermostat/chrono-thermostat use
If you want to use an external programmable thermostat, connect it to the TERM clamps (connector CN7 pin 7-8).
External thermostat
External chrono-thermostat
The stove is enabled with the stove on when the contact is closed.
Room temperature reaches the set value (SET temperature)
When the set room temperature value is reached or the fume temperature has reached the safely value, the stove heat output is set automatically to the minimum
value, MODULATION mode.
If the stove is in the STAND-BY mode, it switches off with a delay equal to a pre-set time after reaching the SET temperature. Restart takes place after occurring
of the condition in which the ambient temperature lowered.
The same situation is obtained when the stove temperature reaches the same level as that set. The modulation status is evident and, if enabled, STANDBY status.
Cleaning the burn pot
When the stove is in the working mode, the “BURN POT CLEANING” mode is activated for the period determined by a pre-set parameter at certain intervals.
Power off of the stove
Hold down P4 button for approx. 2 seconds to switch off the stove. The Auger tube stops immediately and the exhaust blower reaches its maximum speed value.
The FINAL CLEANING phase is performed.
At the end of the period of time set when the fume temperature has fallen below the set value, the fume extractor stops.
Stove off
The display will show the wording OFF. The exhaust blower stops.
Switching on the stove again
It will be possible to switch the stove back on only at the end of the safety period of time set and if the fume temperature has not cooled.
Domestic hot water kit
If the product was purchased with a domestic Kit, after connecting the water inlet and outlet, turn on the stove. When the stove is working and a sanitary hot water
valve is opened, the display will show DOMESTIC WATER. The stove, if it is in the modulation state, will move to maximum power to obtain all the thermal power
available to the domestic hot water system. Once there is no more demand for domestic hot water the stove will return to the thermal power determined based on
the temperature of the water in the stove.
PUFFER probe installation
Once the probe is installed in the AMB terminal, choose the type of system from the Technical Menu. When you have chosen type 1, keys 1 and 2 of the initial
screen offer the possibility to set the temperature for the PUFFER. The stove water is automatically calculated at 10°C higher than the SET PUFFER. Once the
SET PUFFER plus the pre-set Delta have been reached, the stove will move into modulation and then stand-by.
WHAT HAPPENS IF...:
Pellet ignition failure
In case of non-ignition, the display shows the alarm message “NO IGN”.
Power outage
Pr48 = 0
When the power is resumed after an outage, the stove enters the FINAL CLEANING phase and waits until the fume temperature reaches a value below Pr13
Pr48 = T seconds
After a power outage, one of the following conditions may occur depending on the stove previous status:
previous status
power outage duration
new status
switched off any switched off
ignition < T ignition
pellet loading without pre-load < T pellet loading
pellet loading with pre-load any switching off
waiting for flame
< T
waiting for flame
working mode
< T
working mode
burn pot cleaning < T burn pot cleaning
switching off < T switching off
If the power outage duration is longer than T, the stove switches off.
31


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Eva Calor HYDRO 13 KW at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Eva Calor HYDRO 13 KW in the language / languages: English as an attachment in your email.

The manual is 4.77 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Eva Calor HYDRO 13 KW

Eva Calor HYDRO 13 KW User Manual - German - 43 pages

Eva Calor HYDRO 13 KW User Manual - Dutch - 43 pages

Eva Calor HYDRO 13 KW User Manual - French - 43 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info