668782
11
Zoom out
Zoom in
Previous page
1/36
Next page
PELLET STOVES SLIM 4,5 KW
PELLET STOVES SLIM 4,5 KW
PELLET STOVES SLIM 11 KW
PELLET STOVES SLIM 11 KW
REAR WALL P = 40 mm
REAR WALL P = 40 mm
REAR WALL P = 100 mm
REAR WALL P = 100 mm
SIDE WALL L = 300 mm
SIDE WALL L = 200 mm
SIDE WALL L = 250 mm
SIDE WALL L = 150 mm
FLOORING F = - mm
FLOORING F = - mm
FLOORING F = - mm
FLOORING F = - mm
FRONT R = 1000 mm
FRONT R = 1000 mm
FRONT R = 1000 mm
FRONT R = 1000 mm
PELLETI INSERTS
Only AIR-TIGHT STOVES
This stove is an air-tight stove. If properly connected by means of a suction tube, these stoves draw the combustion air and the air necessary for glass
cleaning directly from outside and not from the room where they are installed, preserving the oxygen in the room. Using coaxial tubes the air will be pre-
warmed contributing to improved combustion and lower emissions into the atmosphere. Ideal for passive houses, they offer best comfort at the lowest
cost. The stove works even if not connected to the external air intake.
Besides complying with the minimum clearances set above, we also recommend installing heat-resistant fireproof insulating panels (rock wool, cellular concrete,
etc.).
The following is recommend:
Promasil 1000
Classification temperature: 1000 °C
Density: 245 kg/m
3
Shrinkage at reference temperature, 12 h: 1.3/1000°C %
Cold crushing strength: 1.4 MPa
Bending strength: 0.5 MPa
Reversible thermal expansion: 5.4x10
-6
m/mK
When it is operational, the stove can cause a negative pressure in the room where it is installed. Therefore there should not be in the same room other naked
flame devices, with the exception only of type c stoves (airtight).
Make sure that the stove can draw the necessary quantity of combustion air: this must be from an open space (i.e. a space without exhaust blowers or
providing adequate ventilation) or directly from outside.
Do not install the stove in bedrooms or bathrooms.
Unpack the stove: be careful not to damage the product at the time of unpacking.
Check the stove's legs and adjust them so that the stove is stable.
Place the stove so that the door and any window openings are not against the walls.
After connecting the stove to the combustion air inlet join the coupling device to the vent pipe.
INSTALLATION EXAMPLE:
EXAMPLE OF INCORRECT INSTALLATION:
Exhaust pipes must never be fitted pointing downwards or horizontally so that fumes are discharged directly through the external wall.
11 KW INSERTS 7,5 KW INSERTS
REAR 100 180
LATERAL 100 180
FRONT 1500 1000
FLOOR 50 10
A cm² 500 450
B cm² 500 450
Specific heat capacity: 1.03 Kj/kgK
Thermal conductivity λ:
200 °C 0.07 W/mK
400 °C 0.10 W/mK
600 °C 0.14 W/mK
800 °C 0.17 W/mK
Thickness: 40 mm
T fitting
Cleaning
direction
T fitting
Cleaning
direction
Cleaning
direction
T fitting
T fitting
Cleaning
direction
T fitting
inspection
inspection
External vent with non-
closable grid
External vent with
non-closable grid
Cleaning
direction
11
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Eva Calor Giotto at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Eva Calor Giotto in the language / languages: English as an attachment in your email.

The manual is 5,83 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Eva Calor Giotto

Eva Calor Giotto User Manual - German - 38 pages

Eva Calor Giotto User Manual - Dutch - 38 pages

Eva Calor Giotto User Manual - Dutch - 90 pages

Eva Calor Giotto User Manual - French - 17 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info