Exhaust pipes must never be fitted pointing downwards or horizontally so that fumes are discharged directly through the external wall.
06. INSTALLATION
HANDLING AND UNPACKING
When transporting donot position the product horizontally. Unloading of the product must be performed using lifting means that are suitable and that have
characteristics that are consistent with the weight of the stove. The operator must make sure that during offloading and lifting of the stove there are no persons or
objects nearby. When unpacking, avoid damaging the product with cutters or blunt tools. Keep the packaging out of the reach of children. Remove the screws of
the brackets holding the product to the pallet and put it in position taking care to avoid anything that may block installation or damage the product. Use a lifter or
pallet truck to separate the apparatus from the transport palled using the appropriate opening on its base.
Pay attention to the balance of the product given its size and weight.
In compliance with the current regulations for installation, the stove must be installed in a ventilated place with air that is sufficient to ensure correct combustion
and therefore good operation.
The room must havea volume no less than 20 m³. In order to ensure good combustion (40 m³/h of air) there must be a "combustion air intake" thatreaches an
external wall or a wall of an adjacent room with an external air intake with an 80mm minimum diameter. The adjacent room must not be a bedroom, bathroom, or
contain any fire risks, such as storerooms, garages, combustible materials stores, etc. These air intakes must be made in such a way as to avoid being blocked
internally or externally, and should be covered with a grille, metal net or suitable protection, as long as the minimum diameter is not reduced.
When the stove is on, it can create a depression in the room where it is installed, therefore there must not be any open flame apparatus in the same room (with
the exception of type C boilers (airtight), unless there is a suitable influx of air).
The stove must not be positioned close to curtains, armchairs, furniture or to other flammable materials.
The stove must not be installed in explosive or potentially explosive environments which may become explosive due to the presence of machinery, materials or
dust that can cause greenhouse gas emissions or which can easily ignite with sparks. Before installing the pellet stove, it must be borne in mind that all finishes
or anybeams made of combustible material must be positioned at a suitable distance and outside the irradiation area of the stove itself; furthermore, it must be
borne in mind that in order not to compromise the correct operation of the appliance air must be allowed to circulate inside its housing to prevent overheating, this
is possible by respecting the minimum distances and making ventilation holes with a surface area of 80 cm2.
06.1ELECTRICAL CONNECTION
The electrical connection must be performed by qualified personnel who install circuit breakers upstream of the appliance.
Special attention should be paid when the operation is a supplementary action and all equipment must operate as planned.
Avoid installations with electric cables that run close to fume pipes or hot components that are suitably insulated.
The voltage is 230 V while the frequency is 50 Hz.
The electrical system, at the connection point, must be have a ground connection as required by EEC Regulation 73/23 and EEC 93/98.
Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.
Product:
Forumrules
To achieve meaningful questions, we apply the following rules:
First, read the manual;
Check if your question has been asked previously;
Try to ask your question as clearly as possible;
Did you already try to solve the problem? Please mention this;
Is your problem solved by a visitor then let him/her know in this forum;
To give a response to a question or answer, do not use this form but click on the button 'reply to this question';
Your question will be posted here and emailed to our subscribers. Therefore, avoid filling in personal details.
Register
Register getting emails for Eva Calor Gemma at:
new questions and answers
new manuals
You will receive an email to register for one or both of the options.
Get your user manual by e-mail
Enter your email address to receive the manual of Eva Calor Gemma in the language / languages: English as an attachment in your email.
The manual is 2.19 mb in size.
You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.
If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.
The email address you have provided is not correct.
Please check the email address and correct it.
Your question is posted on this page
Would you like to receive an email when new answers and questions are posted? Please enter your email address.