The stove requires simple and frequent cleaning to guarantee maximum efficiency and correct operation.
The Buyer must carry out regular cleaning of the stove following the instructions contained in this Instruction Manual, and in particular must carry out daily cleaning
before each ignition or refilling of pellets, the ash drawer, the fire pit and the combustion chamber.
Failure to clean and/or routinely maintain the stove can cause: malfunctions, obstruction of the burn pot and pipes, poor or slow combustion, or overheating of the
stove and fire in the hopper.
Eva Stampaggi S.r.l. assumes no criminal and/or civil liability, direct and/or indirect for the malfunction of the stove and for damage to persons or property caused
by the failure/incorrect cleaning and routine maintenance of the stove.
Perform daily cleaning in a completely cold stove as follows:
Turn off the stove using the OFF button and pull out the plug;
Wait until the stove is completely cold;
Empty the ash drawer, vacuuming it or disposing of the ash in the domestic waste;
Vacuum the combustion chamber, ensuring that there are no burning embers remaining. If embers
are still burning, the vacuum cleaner will catch fire;
Remove the ash that collects inside the firebox and on the door.
Clean the glass with a damp cloth or with a ball of damp newspaper dipped in ash. If the operation
is performed with the stove hot there is a risk of the glass exploding.
Caution: Only use a dry cloth to clean the stove. Do not use abrasive material or products that could corrode
or bleach surfaces. At the end of the season, with the last ignition, the pellet remaining in the auger must be
consumed completely. The auger must remain empty to avoid clogging due to solidified sawdust residue
created by moisture.
12. EV STOVE INSTALLATION
When transporting do not position the product horizontally. Unloading of the product must be performed using lifting means that are suitable and that have
characteristics that are consistent with the weight of the stove. The operator must make sure that during offloading and lifting of the stove there are no persons or
objects nearby. When unpacking, avoid damaging the product with cutters or blunt tools. Keep the packaging out of the reach of children. Unscrew from under the
pallet the screws that secure it to the latter and using a regular cart position the stove at the dedicated point paying attention to any impediments that could prevent
installation or damage the product.
Installation place
The pellet stove must be installed in a Technical Room. The technical room must have characteristics that are adequate to installation of the stove: the support
surface must sustain the weight of the stove; it must not be flammable and must be levelled. The same applies for the walls of the room: they must not be made
of flammable materials and must be able to support the weight of any hydraulic components. Observe the safety distances described above.
In compliance with the current regulations for installation, the pellet stove must be installed in a ventilated place with an air flow that is sufficient to ensure correct
combustion and therefore efficient operation. The room must have a volume no less than 20 m3 . In order to ensure good combustion (40m3/h of air) there must be
a "combustion air intake" that reaches an external wall or a wall of an adjacent room with an external air intake (Ø 80mm minimum diameter). The adjacent room
must not be a bedroom or bathroom, or contain any fire risks, such as storerooms, garages, combustible materials stores, etc. These air intakes must be made in
such a way as to avoid being blocked internally or externally, and should be covered with a grille, metal net or suitable protection, as long as the minimum diameter
is not reduced.
When it is operational, the pellet stove can cause a negative pressure in the room where it is installed. Therefore there should not be in the same room other naked
flame devices, with the exception only of type c stoves (watertight) unless they are fitted with their own air flow.
They must not be positioned close to curtains, armchairs, furniture or to other flammable materials.
They must not be installed in explosive or potentially explosive environments which may become explosive due to the presence of machinery, materials or dust
that can cause greenhouse gas emissions or which can easily ignite with sparks. Before starting to install the pellet stove, bear in mind that all the finishes or any
beams in flammable material must be positioned at a safe distance and outside the area of irradiation of the stove itself. Also bear in mind that to avoid compromising
correct operation of the appliance it is essential to create a recirculation of air inside its housing, which prevents overheating. This is possible by observing minimum
distances and by creating ventilation holes.
12.1 HYDRAULIC CONNECTION
Internally, the stove is equipped with all the components for safety: automatic ventilating valve, 3-bar safety valve, expansion vessel, stove safety thermostat and
water pressure sensor.
It is nonetheless MANDATORY to install an anti-condensate valve and a manometer for pressure reading. Remember to discharge the hydraulic system before
switching on the appliance.
The use of hosing is recommended that connects the appliance to the hydraulic system as, in the case of ordinary or extraordinary maintenance, this makes it easy
to move. It is also recommended to install a dirt separator as the electronic pump could capture the dirt of the system and become jammed.
See the PRODUCT DESCRIPTION chapter regarding the distance between the connections and also the size.
The system pressure must range from 0.5 to 2.5 bar. If these thresholds are exceeded, this will trigger the WATER PRESSURE alarm that will cause shutdown of
the product. The recommended pressure is 1.5 bar.
12.2 DOMESTIC WATER KIT
If the stove with DOMESTIC KIT was purchased, the entry of domestic cold water and the outlet of domestic hot water must also be provided. Inside the stove
there is already a three-way valve and a flow switch that automatically comes into operation when there is a demand for domestic hot water. See the PRODUCT
DESCRIPTION chapter regarding the distance between the connections and also the size.
12.3 ELECTRICAL CONNECTION
The electrical connection must be performed by qualified personnel who install circuit breakers upstream of the appliance.
Special attention should be paid when the stove is part of the system and all equipment must operate as planned.
Avoid installations with electric cables that run close to fume pipes or hot components that are suitably insulated.
The voltage is 230V while the frequency is 50 Hz.
The electrical system where it is connected must be fitted with a conductor as required by the Regulations 73/23 EEC and 93/98 EEC.
Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.
Product:
Forumrules
To achieve meaningful questions, we apply the following rules:
First, read the manual;
Check if your question has been asked previously;
Try to ask your question as clearly as possible;
Did you already try to solve the problem? Please mention this;
Is your problem solved by a visitor then let him/her know in this forum;
To give a response to a question or answer, do not use this form but click on the button 'reply to this question';
Your question will be posted here and emailed to our subscribers. Therefore, avoid filling in personal details.
Register
Register getting emails for Eva Calor EV 24 at:
new questions and answers
new manuals
You will receive an email to register for one or both of the options.
Get your user manual by e-mail
Enter your email address to receive the manual of Eva Calor EV 24 in the language / languages: English as an attachment in your email.
The manual is 4.77 mb in size.
You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.
If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.
The email address you have provided is not correct.
Please check the email address and correct it.
Your question is posted on this page
Would you like to receive an email when new answers and questions are posted? Please enter your email address.