16. TROUBLESHOOTING
PROBLEM CAUSE SOLUTION
FIRST START-UP IT MAY BE NECESSARY TO REPEAT THE FIRST LOAD PHASE A FEW TIMES TO FACILITATE THE APPLIANCE INITIAL
START
-
UP AS THE AUGER TUBE IS COMPLETELY EMPTY
AND IT MAY TAKE A SPECIFIC PERIOD OF TIME TO FILL.
DISPLAY SWITCHED OFF
POWER OUTAGE CHECK PLUG AND POWER SUPPLY.
FAULTY ELECTRICAL CABLE CALL TECHNICAL SUPPORT.
INTERRUPTED FUSE IN CONTROL BOARD CALL TECHNICAL SUPPORT.
FAULTY CONTROL BOARD CALL TECHNICAL SUPPORT.
FAULTY DISPLAY CALL TECHNICAL SUPPORT.
ALAR COOL FIRE
ACTIVE ALARM MISSING PELLETS
ACTIVE ALARM IGNITION FAULT
AL6 MISSING PELLETS
AL6 NO FLAME
NO FLAME
POWER OUTAGE CHECK PLUG AND POWER SUPPLY.
NO PELLETS CHECK HOPPER.
AUGER TUBE BLOCKED BY FOREIGN BODY DISCONNECT PLUG, EMPTY HOPPER, REMOVE ANY FOREIGN
BODY, SUCH AS NAILS, ETC.
POOR-QUALITY PELLETS CHANGE PELLET TYPE.
INSUFFICIENT PELLET SET VALUE AT MINIMUM HEAT
OUTPUT CALL TECHNICAL SUPPORT.
POWER OUTAGE SWITCH STOVE ON AND OFF, CHECK PLUG.
ALAR NO IGN
ACTIVE ALARM IGNITION FAULT
AL5 IGNITION FAULT
NO STAB
NO PELLETS CHECK HOPPER.
SAFETY THERMOSTAT TRIGGERED RESET THE MANUAL THERMOSTAT AT THE REAR OF THE STOVE
FAULTY FUME SENSOR CALL TECHNICAL SUPPORT.
AUGER TUBE BLOCKED BY FOREIGN BODY DISCONNECT PLUG, EMPTY HOPPER, REMOVE ANY FOREIGN
BODY, SUCH AS NAILS, ETC.
FAULTY AUGER TUBE MOTOR CALL TECHNICAL SUPPORT.
FAULTY CONTROL BOARD CALL TECHNICAL SUPPORT.
FAULTY EXHAUST BLOWER CALL TECHNICAL SUPPORT.
DIRTY BURN POT CLEAN BURN POT.
TEMPERATURE TOO COLD REPEAT SWITCHING-ON PHASE SEVERAL TIMES, EMPTYING THE
BURN POT UPON EACH TIME.
DAMP PELLETS CHECK PELLET STORAGE LOCATION.
FAULTY GLOW PLUG CALL TECHNICAL SUPPORT.
ALAR COOL FIRE
AL1 POWER OUTAGE
DURING OPERATION THE ELECTRICITY SUPPLY WAS
CUT OFF
IF FOR MORE THAN 20 SECONDS THE STOVE GOES OUT/BURN
POT CLEANING IF FOR LESS THAN 20 SECONDS THE STOVE
RESTARTS IN WORKING MODE
BURN POT CLEANING
WARNING APPEARS AFTER 8 HOURS OF STOVE
OPERATION (4/5 KW MODELS ONLY) 8 HOURS ARE
CUMULATIVE
TO CLEAR THE WARNING, PRESS ALL 3 BUTTONS ON THE
DISPLAY FOR 4-5 SECONDS
IRREGULAR SLOW FLAME
ANTI-EXPLOSION DEVICE PLUG MISSING OR NOT CORRECTLY POSITIONED.
PARTIALLY CLOGGED FLUE PIPE CLEAN FLUE PIPE IMMEDIATELY.
COMBUSTION AIR NOT SUFFICIENT SUCTION PIPE CLOGGED.
CLOGGED STOVE CLEAN BURN POT AND ASH DRAWER.
FAULTY / DIRTY EXHAUST BLOWER GET IT CLEANED BY A SPECIALISED TECHNICIAN CALL
TECHNICAL SUPPORT.
INADEQUATE COMBUSTION AIR SET VALUE CALL TECHNICAL SUPPORT.
ALAR FAN FAIL
EXTRACTION FAULT ACTIVE ALARM
AL4 EXTRACTION FAULT
AL. FAN
FAULTY OR DEFECTIVE EXHAUST BLOWER CALL TECHNICAL SUPPORT.
THE BOARD DOES NOT HEAR THE MOTOR RUNNING
(DEFECTIVE BOARD) CALL TECHNICAL SUPPORT.
ECO/MODULE SET ROOM TEMPERATURE REACHED / CORRECT OPERATION, THE STOVE WORKS AT HEAT OUTPUT LEVEL 1. INCREASE
SET ROOM TEMPERATURE SO THAT APPLIANCE GOES BACK TO "WORKING" MODE.
STOP FIRE
CLN-BURN POT
CLEAN BURN POT
BURN POT CLEANING
PERIODIC CYCLE OF BURN POT CLEANING CORRECT OPERATION.
STAND-BY / ECO STOP / PAUSE SET ROOM TEMPERATURE REACHED / CORRECT OPERATION.
ALAR NEG. PRESS. FAIL
ACTIVE ALARM MISSING DEPRESS-
AL8 NO NEG. PRESS.
AL. PRESS. SWITCH – NEG. PRESS AL
EXCESSIVE OR INADEQUATE FLUE PIPE LENGTH
FIREPLACE NOT COMPLIANT, MAX 6 METRES OF TUBE WITH Ø
80mm AT EACH 90° BEND OR T-CONNECTOR AS 1 METRE OF
TUBE.
CLOGGED OUTLET CLEAN FLUE PIPE / CALL AUTHORISED TECHNICIAN.
BAD WEATHER CONDITIONS STRONG WIND.
ALARM ACTIVE FLOW ALARM
AL FLOW
SENSOR DIRTY, FLUE CLOGGED OR DOOR OPEN. CALL TECHNICAL SUPPORT.
ALAR SAF FAIL
THERMAL-SAFETY ACTIVE ALARM
AL7 THERMAL-SAFETY
AL. SAF.
BOILER TEMPERATURE TOO HIGH
LET STOVE COOL DOWN, MANUALLY RESET THERMOSTAT ON
BACK. IF THE PROBLEM REMAINS UNSOLVED, CONTACT A
SPECIALISED TECHNICIAN.
TEMPORARY POWER OUTAGE LET STOVE COOL DOWN, MANUALLY RESET THERMOSTAT ON
BACK. SWITCH STOVE ON AGAIN.
FAULTY EXCHANGER BLOWER CALL TECHNICAL SUPPORT.
FAULTY THERMOSTAT WITH RESET CALL TECHNICAL SUPPORT.
25
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Eva Calor ARIA 50 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Eva Calor ARIA 50 in the language / languages: English as an attachment in your email.

The manual is 7.33 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Eva Calor ARIA 50

Eva Calor ARIA 50 User Manual - German - 31 pages

Eva Calor ARIA 50 User Manual - French - 31 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info