INSTALLATION WITH WALL FUME OUTLET IS PROHIBITED. INSTEAD THE FUME OUTLET MUST BE ROOF-TYPE AS PROVIDED FOR BY NATIONAL
REGULATIONS.
Eva stampaggi S.r.l. assumes no responsibility for injury to persons and/or damage to property caused by non-observance of the point highlighted
aboverelatingto non-compliant products installed.
Install the stove according to the regulations in force in the country of use.
In Italy, for example, this refers to UNI 10683: 2012, which refers to 4 areas:
a. preliminary activities -are under the jurisdiction and are the responsibility of the reseller/installer at the time of the pre-installation inspection. Preliminary
procedures include:
•installation site suitability verification;
•fume evacuation system suitability verification;
•external air inlet suitabilityverification.
At this stage, the product needs to be checked in order that it can be safely operated and that the relevant technical specifications are met.
The safety conditions must be assessed with a preventive inspection.
Stoves and fireplaces are heating systems and must be installed safelyand comply with the manufacturer's instructions!
b. installation -under the responsibility of the installer. In this phase the installation of the product and the smoke exhaustion system are considered as well as
the handling of topics such as:
•safety distancefrom combustible materials;
•chimney flue construction, smoke ducts, intubated systems and chimney cowls.
c. issuance of supplementary documentation - the responsibility of the installer.
The release of technical documentation must include:
•manual of use and maintenance of the appliance and of the components of the system (e.g smoke ducts, chimney flue, etc.);
•Photocopy or photograph of the chimney flue plate;
•system manual: (if applicable);
•Declaration of Conformity in relation to Ministerial Decree 37/08.
d. control and maintenance - the responsibility of the maintenance technician who must oversee protection and maintenance of the product during its operation
over time.The operator responsible for checking and maintaining the systems for winter and summer climate control carries outtasks in a workmanlike manner
and in observance of applicable regulations. The operator, at the end of these operations, must draw up and sign a technical inspection report in accordance with
the models provided by the provisions of this decree and the implementing rules, in relation to the type and capacity of the system, to be issued to the person who
signs a copy thereby confirming receipt and reading thereof".
The Purchaser must not carry out any structural modification of the stove.
Installation and connection must be carried out by the Purchaser and by qualified technical personnel, in compliance with European (UNI 10683)and national
regulations, local regulations and assembly instructions contained in this Instruction Manual.
Eva Stampaggi S.r.l. assumes no criminal and/or civil liability, direct and/or indirect, for damage to persons or property resulting from non-compliance with the
aforementioned provisions of law, assembly instructions, warnings and general safety rules indicated in this Instruction Manual.
Failure to comply with the installation requirements and/or tampering with the stove can cause: inadequate power and/or abnormal product behaviour, poor smoke
draught, slow combustion, overheating and fire hazard of the stove, fire hazard of the flue duct, a lack of oxygen in the environment where the stove is located.
Eva Stampaggi S.r.l. assumes no criminal and/or civil liability, direct and/or indirect for the malfunction of the stove and for damage to persons or property caused
by non-compliance with the requirements for installation of the stove and/or tampering with it.
The Buyer must request and retain the certification of compliance of the installation, and the connection of the stove, with the provisions of law. In the absence of
such certification Eva Stampaggi S.r.l. assumes no criminal and/or civil liability, direct and/or indirect for the malfunction of the stove and for damage caused to
persons or property, resulting from the use of the product.
Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.
Product:
Forumrules
To achieve meaningful questions, we apply the following rules:
First, read the manual;
Check if your question has been asked previously;
Try to ask your question as clearly as possible;
Did you already try to solve the problem? Please mention this;
Is your problem solved by a visitor then let him/her know in this forum;
To give a response to a question or answer, do not use this form but click on the button 'reply to this question';
Your question will be posted here and emailed to our subscribers. Therefore, avoid filling in personal details.
Register
Register getting emails for Eva Calor Alberta at:
new questions and answers
new manuals
You will receive an email to register for one or both of the options.
Get your user manual by e-mail
Enter your email address to receive the manual of Eva Calor Alberta in the language / languages: English as an attachment in your email.
The manual is 2.3 mb in size.
You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.
If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.
The email address you have provided is not correct.
Please check the email address and correct it.
Your question is posted on this page
Would you like to receive an email when new answers and questions are posted? Please enter your email address.