If there is insufficient supervision of a pump that is functioning automatically, the pump may
break down despite the presence of the overheating safeguard. The user is always responsible
for supervising the device!
MAINTENANCE
Before you carry out checking or cleaning tasks on the pump you must switch it off and
remove the plug from the socket.
Your submersible pump is more or less maintenance-free. The only tasks you must carry out
are as follows:
Carry out a regular visual inspection. Make sure the pump is not damaged. Check the
electrical cable, the plug, the float switch and the float cable for damage too. If you discover
damage, you must take the device to your supplier or an accredited professional. Never
attempt to carry out repairs yourself and never open the pump!
Regularly check that the float switch is working effectively, particularly if you have set the
pump to work automatically.
Regularly remove residues from the float with clean water.
Regularly check (by putting your fingers into the suction openings) whether any dirt (fibres,
residues) has accumulated around the blade. Remove it if this is the case. If you cannot do
so, take the pump to your supplier or to an accredited professional to open the device and
remove the residue.
If you regularly use the pump at different locations, you must rinse with clean water (inside
and out) after each use.
Keep the base of the well (or the tile on which the pump is positioned) free from mud and
residue.
Ensure that the pump does not freeze. Before winter sets in, run the pump dry and store it in
a frost-free location.
DEFECTS CAUSES SOLUTIONS
Defects
Causes
Solutions
Pump does not start
- No electricity
- Float does not switch
- Check electrical supply
- Place the float in a higher position
Pump runs but does
not pump water
- Inlet openings are clogged
- Water drainage pipe is bent or
hose is blocked
- Air around the blade
- Blade is jammed
- Water level is too low (manual
usage)
- Clean them
- Straighten the hose or remove the
blockage
- Switch the pump off and move it from
side to side. Wait until the air has
escaped and switch on again
- Try to remove the blockage or ask a
professional to do so
- Submerge the pump in deeper water
Pump does not switch
off
- Float cannot sink
- Give the float more space
Insufficient water
- Inlet openings are (partially)
blocked
- Too little pumping capacity due
to contamination and dirty
water
- Clean them
- Clean the pump and replace worn
out parts
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Eurom SPV550 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Eurom SPV550 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 0,92 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info