If the device is installed, working or stored in an un-ventilated you
must take measures to prevent fire or explosions caused by
leaked coolant. Ensure that there are absolutely no sources of
ignition (such as fire, heaters, sparking electrical equipment, lit
cigarettes, etc.) in the same room!
The device must be stored in such a way that mechanical defects
are prevented.
Do not install, operate or store the device in a room smaller than
4m² (PAC7.2) / 12 m² (PAC 9.2).
R290 is odourless, which means that you cannot smell leaks!
Persons working on the cooling circuit must be in possession of
the correct qualifications that state the person in question is
competent to use coolant in accordance with a special evaluation
that is recognised by the sector association.
The repairs must be executed on the grounds of the
recommendations of the manufacturer of the device. Maintenance
and repairs that require the assistance of other qualified persons
must be executed under supervision of someone who is
specialised in the use of flammable coolant.
For maximum effect:
Never exceed the recommended area to be cooled.
Do not place the unit in the vicinity of a heat source or in direct
sunlight.
Close windows and doors.
Keep curtains or hatches closed during the sunniest hours in the
day
Keep filters clean
Modify temperature and ventilation settings once the area has
reached the required condition.