39
Safety in relation to coolant R290
1. This device contains the coolant R290. R290 is a coolant that
complies with the relevant European Directives. Never perforate the
coolant circuit. R290 is flammable (GWP 3)!
2. Never use substances other than those recommended by the
manufacturer for the defrosting process.
3. This device must be used and stored in a room that does not
contain sources of ignition, such as open flames or gas and
electrical devices in operation.
4. Do not perforate any of the components of the cooling circuit and
do not set light to the device
5. If the device is installed, working or stored in an un-ventilated you
must take measures to prevent fire or explosions caused by leaked
coolant. Ensure that there are absolutely no sources of ignition
(such as fire, heaters, sparking electrical equipment, lit cigarettes,
etc.) in the same room!
6. The device must be stored in such a way that mechanical defects
are prevented.
7. Do not install, operate or store the device in a room smaller than
15m².
8. R290 is odourless, which means that you cannot smell leaks!
9. Persons working on the cooling circuit must be in possession of the
correct qualifications that state the person in question is competent
to use coolant in accordance with a special evaluation that is
recognised by the sector association.
10. The repairs must be executed on the grounds of the
recommendations of the manufacturer of the device. Maintenance
and repairs that require the assistance of other qualified persons
must be executed under supervision of someone who is specialised
in the use of flammable coolant.
Maximum effect
The maximum surface area, which this air conditioner can cool,
depends on various conditions. Conditions that cause the air conditioner
to cool smaller spaces are, for example:
- Higher outdoor temperature
- Many and/or large windows
- Flat roof
- Many people in the room