474848
21
Zoom out
Zoom in
Previous page
1/48
Next page
21
When dehumidifying, more water is removed from the air. This is
why you must connect a hose to the water drainage hose during
dehumidifying and run this to a drain (at a lower point).
Safety
The PAC12 / 14 is fitted with an overheating safeguard that switches
the unit off if it overheats. If this should occur, you must remove the
plug from the socket and leave the PAC12 / 14 to cool for at least 30
minutes. Remove the cause of overheating - has the device been
(partially) covered? Is it too close to a wall or another obstacle,
preventing it sucking in or dispelling sufficient air?
You can then use the device normally again but keep an eye on it for
the first 30 minutes to ensure there are no further problems. If the
device is showing signs of problems or the overheating recurs, even
though there is no obvious assignable cause, ask your supplier or a
recognised electrician to check/repair the unit.
CLEANING AND MAINTENANCE
Note! Before cleaning or carrying out maintenance work on the air
conditioning unit, always switch off and remove the plug from the
socket! Regular cleaning is vital in order to keep the unit in good
working order!
Cleaning the housing
Use a soft, damp cloth to wipe the housing.
Never use aggressive cleaning products, petrol, detergent,
chemically-impregnated cloths or other cleaning solutions. These
could damage the housing. Never spray the unit and ensure that
water never penetrates the device! Dry the unit with a soft cloth.
Cleaning the filters
Clean the filters once every two weeks; a unit with dirty filters will
never work properly. The 4 filters can be found behind the air inlet
grilles on the sides and at the rear. You can easily open these grilles
and remove the filters. Use a vacuum cleaner or gently beat the filter
to remove loose dust and dirt. Rinse the filter with tepid water (not
hotter than 40°C) with a mild, neutral cleaning product. Let the filters
dry thoroughly in the shade before replacing in the unit. Take care!
Never use the air conditioning unit without the filters!
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Eurom PAC 14 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Eurom PAC 14 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 0,67 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info