The dehumidification extracts more water from the air. This is why we recommend connecting
a hose to the water drainage constant B during dehumidification and leading it to a (lower)
water drainage point (constant drainage).
If the water pump is defective but you would still wish to use the device, connect a hose for
constant drainage to one of the water drainage points. It will be possible for the device to work
normally.
Safety
The PAC12.2 / 14 is fitted with an overheating safeguard that switches the unit off if it
overheats. If this should occur, you must remove the plug from the socket and leave the
PAC12.2 / 14 to cool for at least 30 minutes. Remove the cause of overheating - has the device
been (partially) covered? Is it too close to a wall or another obstacle, preventing it sucking in or
dispelling sufficient air?
You can then use the device normally again but keep an eye on it for the first 30 minutes to
ensure there are no further problems. If the device is showing signs of problems or the
overheating recurs, even though there is no obvious assignable cause, ask your supplier or a
recognised electrician to check/repair the unit.
CLEANING AND MAINTENANCE
Note! Before cleaning or carrying out maintenance work on the air conditioning unit, always
switch off and remove the plug from the socket! Regular cleaning is vital in order to keep the
unit in good working order!
Cleaning the housing
Use a soft, damp cloth to wipe the housing.
Never use aggressive cleaning products, petrol, detergent, chemically-impregnated cloths or
other cleaning solutions. These could damage the housing. Never spray the unit and ensure
that water never penetrates the device! Dry the unit with a soft cloth.
Cleaning the filters
Clean the filters once every two weeks; a unit with dirty filters will never work properly.
Open the grill of the air inlet and remove the filter.
Clean the filter in lukewarm water (max. 40°C), possibly with a neutral cleaning agent. Allow
the filter to dry thoroughly in the shade.
Put the filter back into the grill and the grill back into the device.
Take care! Never use the air conditioning unit without the filters!
End of season cleaning
If the device is to be stored for a long period, you must take the following measures!
Open the water drainage point (11) and allow the condensed water to drain out completely.
Run the unit for a few hours on fan function so that the unit is completely dry inside.
Then switch the air conditioning unit off, remove the plug from the socket and:
Clean the filter and either put it back or replace it.
unscrew the waste pipe from the device in order to prevent damage;
pack the air conditioning unit in its original packaging or in a plastic bag and place in a dry
place for storage, not smaller than 10m². Never place a heavy object on the unit.
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Eurom PAC 12.2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Eurom PAC 12.2 in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 0,64 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info