- 4 -
GENERAL
Carefully read the following important information regarding installa-
tion safety and maintenance. Keep this information booklet accessible
for further consultations. The appliance has been designed for use in
the ducting version (air exhaust to the outside ), filtering version (air
circulation on the inside ) or with external motor.
SAFETY PRECAUTION
1. Take care when the cooker hood is operating simultaneously with an
open fireplace or burner that depend on the air in the environment and
are supplied by other than electrical energy, as the cooker hood re-
moves the air from the environment which a burner or fireplace need
for combustion. The negative pressure in the environment must not
exceed 4Pa (4x10-5 bar). Provide adequate ventilation in the environ-
ment for a safe operation of the cooker hood.
Follow the local laws applicable for external air evacuation.
Before connecting the model to the electricity network:
- control the data plate (positioned inside the appliance) to ascertain
that the voltage and power correspond to the network and the socket is
suitable. If in doubt ask a qualified electrician.
2. WARNING !
In certain circumstances electrical appliances may be a danger
hazard.
A) Do not check the status of the filters while the cooker hood
is operating
B) Do not touch bulbs or adjacent areas, during or straight after
prolonged use of the lighting installation.
C) Flambè cooking is prohibited underneath the cooker hood
D) Avoid free flame, as it is damaging for the filters and a fire
hazard
E) Constantly check food frying to avoid that the overheated
oil may become a fire hazard
F) Disconnect the electrical plug prior to any maintenance.
G) This appliance is not intended for use by young children or
infirm persons without supervision
H) Young children should be supervised to ensure they do not
play with the appliance
I) There shall be adequate ventilation of the room when the
rangehood is used at the same time as appliances burning gas
or other fuels
L) There is a risk of fire if cleaning is not carried out in accord-
ance with the instructions
INSTALLATION INSTRUCTIONS
Assembly and electrical connections must be carried out by
specialised personnel.
• Electric Connection
The appliance has been manufactured as a class II, therefore no earth
cable is necessary.
The connection to the mains is carried out as follows:
BROWN = L line
BLUE = N neutral
If not provided, connect a plug for the electrical load indicated on the
description label. Where a plug is provided, the cooker hood must be
installed in order that the plug is easily accessible.
An omnipolar switch with a minimum opening of 3mm between con-
tacts, in line with the electrical load and local standards, must be placed
between the appliance and the network in the case of direct connection
to the electrical network.
The minimum distance between the support surfaces of the cooking
pots on the cooker top and the lowest part of the cooker hood must be
at least 65 cm.
If a connection tube composed of two parts is used, the upper part must
be placed outside the lower part.
Do not connect the cooker hood exhaust to the same conductor used
to circulate hot air or for evacuating fumes from other appliances gen-
erated by other than an electrical source.
In the case of assembly of the appliance in the exhausting version
prepare the hole for evacuation of the air.
INSTALLATION
The following instruction should be followed to carry out the correct
installation of the cooker hood.
1) Mounting of the cooker hood on the lower side of the cupboard.
2) Selection of the version (extraction or filtration)
Mounting the cooker hood on the lower side of the cupboard. This
appliance must be fitted to a cupboard or other suitable support. For
fixing use 4 screws suitable for the cupboard, using the hole in Fig.1.
When mounting align the front of the cooker hood to the door of the
cupboard and regulate the L wall spacer through the screws marked
P (Fig. 2). The rear of the appliance must then align with the cupboard.
EXTRACTION THROUGH AN OUTSIDE WALL
The appliance expels the fumes through an outside wall or a duct. It is
necessary to buy a telescopic pipe in accordance with the standards
in use and connect it to flange B (Fig. 1).
RECIRCULATION
To transform the cooker hood from the extraction version to the re
circulating one ask your supplier for an activated carbon filter. The
activated carbon filter cleans the air of the room. This filter is not
washable or re-usable and must be substituted at least every 4 months.
Saturation of the activated charcoal depends on how often the appliance
is used, the type of kitchen and how regularly the grease filter is cleaned.
The filter must be fitted to the extracting group cooker hood in the
centre of the fan grille by twisting it by 90 degrees until it is gripped
securely. Remove the grill (G) fig. 2 to carry out this operation.The
clean air is returned into the room through a connecting tube passing
inside the cupboard and connected to the ring B (Fig. 1).
USE AND MAINTENANCE
It is recommended to operate the appliance prior to cooking.
It is recommended to leave the appliance in operation for 15 minutes
after cooking is terminated in order to completely eliminate cooking
vapours and odours.
The proper function of the cooker hood is conditioned by the regularity
of the maintenance operations, in particular, the active carbon filter.
The anti-grease filters capture the grease particles suspended in the
air, and are therefore subject to clogging according to the frequency of
the use of the appliance.
In order to prevent fire hazard, it is recommendable to clean the filter
at a maximum of 2 months by carrying out the following instructions:
- Remove the filters from the cooker hood and wash them in a solution
of water and neutral liquid detergent, leaving to soak.
- Rinse thoroughly with warm water and leave to dry.
- The filters may also be washed in the dishwasher.
The aluminium panels may alter in colour after several washes. This
is not cause for customer complaint nor replacement of panels.
The active carbon filters purify the air that is replaced in the environ-
ment. The filters are not washable nor re-useable and must be re-
placed at maximum every four months. The saturation of the active
carbon filter depends on the frequency of use of the appliance, by the
type of cooking and the regularity of cleaning the anti-grease filters.
Clean the fan and other surfaces of the cooker hood regularly using
a cloth moistened with denatured alcohol or non abrasive liquid deter-
gent.
• The illumination installation is designed for use during cooking and
not for prolonged general illumination of the environment. Prolonged
use of the illumination installation notably reduces the duration of the
bulb.
THE MANUFACTURER DECLINES ALL RESPONSIBILITY
FOR EVENTUAL DAMAGES CAUSED BY BREACHING
THE ABOVE WARNINGS.
ENGLISH
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Eudora BDA Elin EBD1360 X at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Eudora BDA Elin EBD1360 X in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 0,24 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info