10 Technical data
Electrical data
Input phases from grid or installation
one or three (depends on the
configuration)
Connection terminals
35 mm2
Nominal voltage
230 V / 400 V +5 %,-5 %
Input power
Depends on the configuration, max.
44 kW
Input current
Depends on the configuration, max. 3 x
64 A
Number of charging spots (sockets)
2
Charging socket type
62196-2 "Type 2"
Socket physical protection
Lid cover (optional locking when not in
use)
Charging coupler protection
Socket locking mechanism during
charging
Charging socket max. output power
(current)
Depends on the configuration; max
22 kW (3 x 32 A)
Simple shutdown for maintenance
fuse switch disconnector on input
Overcurrent protection of each socket
40 A - Type C
Additional thermal/logical protection
of the socket, based on deviations from
PWM setting
* I/Ipwm >105 % during T>1000s
* I/Ipwm>110 % during T>100s
* I/Ipwm>120 % during T>10s
Standby energy consumption
Depends on the configuration: max.
20 W with network switch and GPRS
modem installed
Differential protection of the socket
RCD (ground leakage current)
Type A or Type B 30 mA compliant with
IEC 61008
Energy metering
Embedded smart energy meters
Contactors
Disconnecting all phases and neutral
line
Voltage monitoring
Monitors voltage on the socket level to
detect contactor welding or other
power supply faults
Overvoltage protection of the station
(optional)
Station can be equipped with Type B2
if connected to the electricity
distribution network; Type C if
connected to an existing installation.
Overcurrent protection of the
overvoltage protection (optional)
63 A (fuse)
EVSE standards compliance
IEC 61851-1 supports Mode 3
charging
RFID identification data
Standards
ISO/IEC 14443A and ISO/IEC 15693
Supported cards
Mifare® Classic 1K (1KByte), Mifare®
52


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Etrel Gen 6 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Etrel Gen 6 in the language / languages: English as an attachment in your email.

The manual is 1.77 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info