2708
51
Zoom out
Zoom in
Previous page
1/54
Next page
101 INSTALLATION
Electrical connection
A view of the power cable is shown schematic
below:
2 phase connection
2 positive + 2 negative 2 2N a.c. 230 V
The fuse box in your home must be fitted with
a 16 A fuse.
negative connection N1 (blue)
negative connection N2 (brown)
positive connection L1 ( grey)
positive connection L2 ( black)
2 positive + 1 negative 2 2N a.c. 400 V
The fuse box in your home must be fitted with
a 16 A fuse.
negative connection N (blue and brown)
positive connection L1 (grey)
positive connection L2 (black)
Do not connect the 3rd phase
The next deviant connections are possible too:
1 phase connection
1 positive + 1 negative 1N a.c. 230 V
The fuse box in your home must be fitted with
a 32 A fuse.
negative connection N (blue and brown)
positive connection L (grey and black)
3 phase connection
3 positive without negative 3 a.c. 230 V
The fuse box in your home must be fitted with
a 16 A fuse.
positive connection L1 (grey)
positive connection L2 (black)
positive connection L3 (blue and brown)
L1,
grey
L2,
black
N1,
blue
N2,
brown
ground
yellow/green
blue
brown
grey
black
yellow/green
N1 N2 L1 L2
230V
230V
NL1L2
230V
230V
blue
brown
grey
black
yellow/green
NL
230V
blue
brown
grey
black
yellow/green
L3 L2 L1
230V
230V
230V
blue
brown
grey
black
yellow/green
Electrical connection
The model number, power supply and
connected load are specified on the data
plate.
The data plate is attached to the base of the
appliance.
The connection cable is of the type Y.
This means that the connection cable may
only be replaced by the manufacturer, the
service organisation or similarly qualified
persons, in order to prevent dangerous
situations.
Refer to the figure below for the wiring
diagram, which can also be found on the
underside of the appliance.
If you want to make a fixed connection, make
sure that a multi-polar switch with a contact
separation of at least 3 mm is fitted in the
supply line.
100 INSTALLATION
51


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Etna T300 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Etna T300 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 2,64 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Etna T300

Etna T300 User Manual - English, German, Dutch, French - 54 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info