692135
9
Zoom out
Zoom in
Previous page
1/16
Next page
NL .......................................................................................................................................................................4
EN .......................................................................................................................................................................7
DE .....................................................................................................................................................................10
FR .....................................................................................................................................................................13
3
Let op:
Het uitvoeren van deze instructie door een niet bevoegd monteur kan leiden tot gevaarlijke situaties.
Etna is niet aansprakelijk voor gevolgen (het ontstaan van een gevaarlijke situatie en/of schaden aan
personen en goederen) ontstaan door het foutief uitvoeren van deze instructie door monteurs die niet in
dienst zijn van de Etna servicedienst. Gevolgschade ontstaan door ondeskundig uitvoeren van deze instructie wordt
niet gehonoreerd.
Deze ombouwset bestaat uit originele onderdelen. Originele onderdelen worden gekeurd op geschiktheid en
veiligheid tijdens de typekeuring van het toestel. Regelmatig uitgevoerde partijkeuringen garanderen de kwaliteit van
originele onderdelen.
Etna adviseert het ombouwen van een toestel naar een andere gassoort te laten uitvoeren door een monteur van de
Etna servicedienst. Bel de Etna servicedienst voor het maken van een afspraak met de servicemonteur.
4
Neem bij problemen met het
ombouwen of bij storingen
contact op met de Etna
servicedienst.
ETNA Nederland
www.etna.nl
ETNA Belgie
www.etna.be
9
Check for gas tightness
Use leak spray to check the gas tightness when the appliance is connected to the gas supply:
1. Seal the injector.
2. Open the gas tap. Attention; press and open taps with thermo electric safety device and keep them pressed!
3. Spray leak spray on the connections (such as gas duct/burner, gas duct / gas) and check for gas tightness (see fig. L).
Check the gas tightness with a pressure pump (see illustration M) when the appliance is not connected to the
gas supply:
1. Connect the pressure pump to the gas pipe and close all gas taps.
2. Increase the pressure to 150 mbar and close the tap (see illustration M/10) between the pressure pump and the
pressure gauge (see illustration M/8). Check the pressure. The maximum pressure loss may amount to 5 mbar per
minute. After checking, open the tap (see illustration M/10) between the pressure pump and the pressure gauge.
3. Open one of the taps and close the corresponding injector.
Attention; press and open taps with thermo electric safety device and keep them pressed!
4. Increase the pressure to 150 mbar and again close the tap between the pressure pump and the pressure gauge.
Check the pressure. The maximum pressure loss may amount to 5 mbar per minute.
5. Repeat this test for all taps and injectors.
Checking operation
Ignite the burners. Check whether the flame profile is uniform and stable for the complete flexibility ratio.
Important for this is that:
1. the flame does not smother in simmer rate
2. the burner does not ‘ blow off’ at maximum burning (to be recognized in flames that are at a distance from
the burner in combination with a ‘hissing’ sound)
3. there are no long yellow flames
L
7
8
9
10
M
Gas table
G25.3 - 25 mbar G30 - 30 mbar
Burner
Inscription injector Inscription injector
Auxiliary - 1,0 KW
0.80 0.50
Semi rapid - 1,75 KW
1.02 0.66
Rapid - 3,0 KW
1.32 0.87
Wok - 3,50 KW (KGG673)
1.37 0.94
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Etna KGG673ZTA at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Etna KGG673ZTA in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 2,16 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Etna KGG673ZTA

Etna KGG673ZTA Installation Guide - English - 2 pages

Etna KGG673ZTA User Manual - English - 36 pages

Etna KGG673ZTA Installation Guide - German - 2 pages

Etna KGG673ZTA User Manual - German - 36 pages

Etna KGG673ZTA Installation Guide - Dutch - 2 pages

Etna KGG673ZTA User Manual - Dutch - 36 pages

Etna KGG673ZTA Installation Guide - French - 2 pages

Etna KGG673ZTA User Manual - French - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info