INSTALLATIE
Installation
General
The fitting of the appliance should only be
carried out by a registered Corgi gas fitter.
The appliance is not connected to the flue gas
outlet channel.
Electrical connection 230 V - 50 Hz.
The electrical connection must comply
with national and local regulations. For the
Netherlands this includes the NEN 1010
amongst other standards.
Wall socket and plug must be accessible at
all times.
Gasconnection: RC 1/2” (ISO 7/1-RC 1/2)
The gas connection must comply with
national and local regulations. For the
Netherlands this includes the GAVO
regulations (NEN 1078). Amongst other
things these regulations instruct that:
– only approved materials are to be used.
Attention:
The type of gas and the country for which the
appliance has been designed are indicated on
the ratings plate. The appliance is set in the
factory for G25 (natural gas) with a pressure
of 25 mbar. Appliance category 12L.
Connect the oven directly to the mains.
This is because the oven can reach high
temperatures. It can also be connected
with a specially designed gas hose. Attach
this hose at the side of the oven to prevent
it touching any hot parts. A gas tap, which
is easily accessible, should always be
used for the appliance.
Built-in dimensions
850
600
(EFG667/687/688V)
500
(EFG607H)
600
fig. 10
front view side view
Table burner information
Combustion with G25 low setting
Rating nominal
Burner position Rear left Rear right Front right Front left FL (EFG688VRVS)
Burner Semi rapid Semi rapid Simmer Rapid Wok
Diameter [mm] 94 94 72 125 148
Flow [l/h] 193,8 193,8 110,7 332,2 420,82
Gas type G25/25mbar G25/25mbar G25/25mbar G25/25mbar G25/25mbar
Rating nominal (kW) 1,75 1,75 1,00 3,00 3,8
Rating nominal (kW) 0,52 0,52 0,30 0,75 1,6
37


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Etna EFG667 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Etna EFG667 in the language / languages: English, Dutch as an attachment in your email.

The manual is 1,44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Etna EFG667

Etna EFG667 Additional guide - Dutch - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info