GAS CONNECTION
Fig. 2
1/2
2
1
3
4
5
L
N
A
Applance type Supply single-phase 230 V~
Type of cable section
All gas + elett. oven Rubber H05 RR-F
The appliance must be connected to the gas piping in a workmanlike
way and in conformity with the regulations in force which lay down
the installation of a safety valve at the end of the piping.
For butane and propane a pressure reducer conforming to the
standards in force may perform this task.
The seal gaskets must be in accordance with rules.
Once the gas appliance has been connected, check the connection
seal by means of soapy water.
The possible connections are:
We recommend to check wether the appliance has been foreseen
for the kind of gas distributed.
- by rigid pipe in iron or copper
- by flexible tube in stainless steel with continuing wall, with
mechanical connection in accordance with rules. The tube must
be directly connected to the manifold elbow (see Fig.2).
ELECTRICAL CONNECTION
REPLACEMENT OF THE CABLE
In
case the cable is damaged, replace it in accordance with the
following instructions:
- open the box of the supply board as described on the picture
below;
- unscrew screw A fixing the cable;
- replace the cable with one of the same lenght and in accordance
with the features described on the table; switch the appliance
off, and close the gas tap
- the green-yellow earth wire must be connected to the terminal
  and it must be about 10 mm longer thean the live wires;
- the blue neutral wire must be connected to the terminal marked
with letter N;
- the live wire must be connected to the terminal marked with letter
L.
This appliance must be earthed by law. Before connecting
the
appliance to the electrical supply, check that the earth
system in your house is working correctly.
Check that unit voltage and power, marked on the rating plate
applied on the appliance, are correct for the supply. If an fixed
appliance
is not equipped with supply cable and plug, the power
supply
must be fitted with a disconnect switch in which the distance
between contacts permits total disconnection in accordance with
overvoltage category III, as required by installation regulations.
Be sure that the earth wire green/yellow is not interrupted by
the switch.
Important: The wires in the mains lead are so coloured:
- green/yellow = earth " "
- blue = neutral N
- brown = live L
The wire coloured green/yellow must be connected to the terminal
in the plug which is marked with letter 'E' or by the earth symbol
or coloured green or green/yellow. The wire coloured blue must
be connected to the terminal which is marked with letter 'N' or
coloured black. The wire coloured brown must be connected to
the terminal which is marked with letter 'L' or coloured red. The
supply cable must not come into contact with any component the
temperature of which exceeds the ambient temperature by 50°C.
If a plug is used for connection, the plug to be connected to the
supply cable and the socket to which it is connected must be of
the same type (conforming to the standards). Easy access to the
plug or the switch is ensured once the appliance is installed. Ensure
that there is sufficient cable allowed for any subsequent removal
of the unit. If the plug is non-rewireable, pay attention to the
following points: the plug must never be cut by the supply cord.
There is shock hazard when this plug is inserted in a socket-outlet
elsewhere in the house. Never use the plug without the fuse cover
fitted. Referring to the pertinent spare parts, apply to the appliance's
supplier.
Connection of the appliance to the power mains should be done
by a licensed electrician familiar with local safety regulations.
3 x 2,5 mm
2
29
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Etna 1995 VW RVS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Etna 1995 VW RVS in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 0,61 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info