INSTALLATION
The appliance must be installed by qualified
staff working in accordance with the regula-
tions in force.
Before installing, ensure that the appliance
is correctly preset for the local distribution
conditions (gas type and pressure).
The presettings of this appliance are indi-
cated on the nameplate shown on the cover.
This appliance is not connected to a flue gas
extractor device. It must be installed and
connected in accordance with the regulations
in force.
This appliance may only be installed and may
only operate in rooms permanently ventilated
in accordance with national regulations in
force.
VENTILATION
The rooms in which gas appliances are in-
stalled must be well ventilated in order to al-
low correct gas combustion and ventilation.
The air flow necessary for combustion is at
least 2 m
3
/h for each kW of rated power.
POSITIONING
Remove the packaging accessories, includ-
ing the films covering the chrome-plated and
stainless steel parts, from the cooker.
Position the cooker in a dry, convenient and
draft-free place. Keep at an appropriate dis-
tance from walls which may be damaged by
heat (wood, linoleum, paper, etc.).
The cooker may be free-standing (class 1)
or between two units (in class 2 st 2-1) the
sides of which must withstand a temperatu-
re of 100°C and which must not be higher
than the working table.
CONNECTING TO THE GAS SUPPLY
Before connecting the cooker, check that it
is preset for the gas to be used.
The connection is on the right; if the pipe has
to pass behind the cooker, it must be kept low
down where the temperature is about 50°C.
- Rigid connection (see fig. 3 A and B)
The connection to the mains gas supply
may be made using a rigid metal pipe or
with a metal hose. Remove the hose
connector (if already fitted) and screw the
rigid union onto the threaded connection
of the gas train (see fig. 3 A). The union for
rigid connection may already be fitted on
the gas train, or may be amongst the cooker
accessories. Otherwise, it can be obtained
from your dealer.
If national regulations permit, a metal hose
complying with the national standards can
be screwed directly onto the threaded
connection of the gas train, fitting a seal
(see fig. 3B).
However, users are strongly recommended
always to fit the rigid union.
- Connection using a rubber hose (see fig.
3 C and D)
Connect a rubber hose carrying the
conformity mark currently in force to the hose
connector. The hose must be replaced at
the date indicated at the latest, and must
be secured at both ends using standard
hose clamps. It must be absolutely
accessible to allow its condition to be
checked along its entire length.
CAUTION:
- Use of the hose connector is only
permitted for free-standing installation.
If the appliance is installed between two
class 2 st. 2-1 unions, the rigid union is
the only form of connection permitted.
IMPORTANT:
- After installation, check that the
connections are airtight.
- Use only standard rubber hoses.
- Avoid sharp bends in the pipe and keep it
well way from hot surfaces.
- References to the regulations covering the
gas connection to the appliance: ISO 7-1
(NL)
CONNECTING TO THE ELECTRICAL
MAINS
Before making the connection, check that:
- the mains voltage is as indicated on the
nameplate;
Installation
GB
334821/01 20-11-2001, 17:1838
38


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Etna 1611vwt at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Etna 1611vwt in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 0,33 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info